Tecnhical specifications of Sick DIN Rail Safe Signal Processing SRB402EM 101170840:

SpecValue
MountingSnaps onto standard DIN rail to EN 60715
Terminationrigid or flexible, Screw connection, plug-in
Width22.5 mm
Height120 mm
Depth121 mm
SpecificationValue
Housing materialGlass-fibre reinforced thermoplastic, ventilated
Gross weight250 g
PFH value, Stop 02.00 x 10⁻⁸ /h
MountingSnaps onto standard DIN rail to EN 60715
Terminationrigid or flexible, Screw connection, plug-in
Cable section, minimum0.25 mm²
Cable section, maximum2.5 mm²
Tightening torque of Clips0.6 Nm
Width22.5 mm
Height120 mm
Depth121 mm
Degree of protection of the enclosureIP40
Degree of protection of the mounting spaceIP54
Degree of protection of clips or terminalsIP20
Ambient temperature-25 ... +45 °C
Storage and transport temperature-40 ... +85 °C
Resistance to vibrations10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock10 g / 11 ms
Rated impulse withstand voltage Uimp4 kV
Frequency range50 Hz, 60 Hz
Operating voltage24 VAC -15 % / +10 %24 VDC -15 % / +20 %
Ripple voltage10 %
Rated operating voltage24 VDC
Electrical power consumption1 VA
Contact resistance, maximum0.1 Ω
Drop-out delay, maximum35 ms
Pull-in delay at automatic start, maximum, typically30 ms
Material of the contacts, electricalAgSn0. self-cleaning, positive drive
Switching capacity, minimum10 mA
Switching capacity, maximum2 A
Conduction resistance, maximum40 Ω
Get A Quote for Sick DIN Rail Safe Signal Processing SRB402EM part no: 101170840 at the best price. Here are the brief Technical Specifications of SRB402EM, 101170840 are Glass-fibre reinforced thermoplastic, ventilated design, ensuring robust protection and longevity. The sensor is easy to install, Snaps onto standard DIN rail to EN 60715 and the Termination is handled via rigid or flexible, Screw connection, plug-in methods, allowing for both rigid or flexible wiring options. With dimensions of 22.5 mm in Width, 120 mm in Height, and 121 mm in Depth, this compact sensor fits seamlessly into various setups. It operates within a Frequency range of 50 Hz, 60 Hz with an Operating voltage of 24 VAC -15 % / +10 %24 VDC -15 % / +20 %. The Rated operating voltage is 24 VDC and the Electrical power consumption is minimal at just 1 VA. It's Time to get a Quote for your requirement of Sick DIN Rail Safe Signal Processing. We guarantee unmatched pricing and unparalleled support compared to other Distributors.