A9N61512 | Schneider C60H 1 Pole 20A C Curve Breaker
+91 79955 44066 sales@indmall.in

A9N61512: Schneider C60H 1 Pole 20A C Curve Breaker

Technical Specifications of Schneider C60H 1 Pole 20A C Curve Breaker A9N61512:

SpecValue
Productor Component typeMiniature circuit-breaker
Mounting ModeFixed
Mounting Support35 mm symmetrical DIN rail
Tightening torquePower circuit: 2.5 N.m top or bottom

Schneider C60H 1 Pole 20A C Curve Breaker A9N61512 Technical Specifications:

SpecificationValue
RangeActi9
Product or component typeMiniature circuit-breaker
Device short nameC60H-DC
Device applicationDistribution
Poles description1P
Number of protected poles1
[In] rated current20 A at 25 °C
Network typeDC
Trip unit technologyThermal-magnetic
Breaking capacity10 kA Icu at 220 V DC conforming to EN 60947-210 kA Icu at 220 V DC conforming to IEC 60947-26 kA Icu at 250 V DC conforming to EN 60947-26 kA Icu at 250 V DC conforming to IEC 60947-220 kA Icu at 110 V DC conforming to EN 60947-220 kA Icu at 110 V DC conforming to IEC 60947-2
Utilisation categoryCategory A conforming to EN 60947-2Category A conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-2Yes conforming to EN 60947-2
Network frequency50/60 Hz
[Ue] rated operational voltage250 V DC
[Ui] rated insulation voltage500 V DC conforming to IEC 60947-2500 V DC conforming to EN 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN 60947-26 kV conforming to IEC 60947-2
Contact position indicatorYes
Control typeToggle
Local signallingON/OFF indication
Mounting modeFixed
Mounting support35 mm symmetrical DIN rail
Net weight0.128 kg
ColourWhite
Tightening torquePower circuit: 2.5 N.m top or bottom
Pollution degree3 conforming to EN 60947-23 conforming to IEC 60947-2
Operating altitude2000 m
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Get A Quote for Schneider C60H 1 Pole 20A C Curve Breaker A9N61512 at the best price. Here are the brief Technical Specifications of A9N61512 are the product is a Miniature circuit-breaker with a rated current of 20 A at 25 °C, designed specifically for DC applications. It supports an operational voltage of 250 V DC and an insulation voltage of 500 V DC conforming to IEC 60947-2500 V DC conforming to EN 60947-2 standards. The control type is a Toggle, ensuring easy and safe operation. The Acti9 C60H-DC is designed for Fixed installation on a 35 mm symmetrical DIN rail, making it ideal for industrial and commercial environments. It's Time to get a Quote for your requirement of Schneider C60H 1 Pole 20A C Curve Breaker. We guarantee unmatched pricing and unparalleled support compared to other Distributors.