ATV320U40M3C412 | Schneider Altivar Solar 4 kW VSD | IndMALL
+91 79955 44066 sales@indmall.in

ATV320U40M3C412: Schneider Altivar Solar 4.0kW VSD

technical Specifications of Schneider Altivar Solar 4.0kW VSD ATV320U40M3C412:

SpecValue
Nominal output current17.5 A
Switching frequency2...16 kHz adjustable4...16 kHz with derating factor
Power factor0.615 at 230 V
Electrical connectionScrew terminal, clamping capacity: 0.5...1.5 mm² for analog inputScrew terminal for analog outputScrew terminal

Schneider Altivar Solar 4.0kW VSD ATV320U40M3C412 Technical Specifications:

SpecificationValue
Analogue input number3
With safety function Safe Speed Monitor (SSM)FALSE
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Number of Units in Package 212
Ambient air temperature for operation-10…50 °C without derating50…60 °C with derating factor
Nominal output current17.5 A
Format of the driveCompact
Local signalling1 LED (red) for drive fault1 LED (red) for CANopen error1 LED (green) for CANopen run
Minimum switching currentRelay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Switching frequency2...16 kHz adjustable4...16 kHz with derating factor
Acceleration and deceleration rampsLinearUSCUSRamp switchingAcceleration/deceleration ramp adaptationAcceleration/deceleration automatic stop with DC injectionAutomatic adaptation of ramp if braking capacity exceeded, by using resistorLinear adjustable separately from 0.01 to 6000 s
Discrete input typeSTO safe torque off, 24 V DC, impedance: 1.5 kOhmDI1...DI6 logic inputs, 24 V DC (30 V)DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Analogue output typeSoftware-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bitsSoftware-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Base load current at high overload17.0 A
Discrete input logicPositive logic (source)Negative logic (sink)
Data format8 bits, configurable odd, even or no parity
With sft fct Safe Stop 2 (SS2)FALSE
Power factor0.615 at 230 V
Communication port protocolModbus serialCANopen
Package 2 Height75 cm
Unit Type of Package 2S06
Electrical connectionScrew terminal, clamping capacity: 0.5...1.5 mm² for analog inputScrew terminal for analog outputScrew terminal
Operating positionVertical +/- 10 degree
Width140 mm
Package 1 Height24.5 cm
Power dissipation in WFan: 140 W at 200 V, switching frequency 4 kHz
Maximum input current23.8 A
Package 1 Length26.8 cm
Assembly styleWith heat sink
Braking torque170 % with braking resistor
Overvoltage categoryII
Prospective line Isc5 kA
Depth158.0 mm
Short-circuit protectionthermal protection
4 quadrant operation possibleTRUE
Package 1 Weight2.605 kg
With safety function Safe Direction (SDI)FALSE
Motor power kW4.0 kW for heavy duty
Transient overtorque170…200 % of nominal motor torque
Package 1 Width19.1 cm
Package 2 Length80 cm
Net Weight2.2 kg
Number of Units in Package 11
Discrete output typeOpen collector DQ+ 0…1 kHz 30 V DC 100 mAOpen collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input typeAI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bitsAI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bitsAI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
Maximum output voltage240 V
Apparent power8.3 kVA at 240 V (heavy duty)
Ambient air temperature for storage-25…70 °C
Mounting modeWall mount
Maximum switching currentRelay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DCRelay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V ACRelay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Speed accuracy+/- 10 % of nominal slip 0.2 Tn to Tn
Protection typeInput phase breaks: driveOvercurrent between output phases and earth: driveOverheating protection: driveShort-circuit between motor phases: driveThermal protection: drive
Range of productAltivar Solar
Relay output number2
[Us] rated supply voltage200...240 V - 15...10 %
EMC filterWithout EMC filter
Ambient air transport temperature-25…70 °C
Nominal switching frequency4 kHz
IP degree of protectionIP20
Get A Quote for Schneider Altivar Solar 4.0kW VSD ATV320U40M3C412 at the best price. Here are the brief Technical Specifications of ATV320U40M3C412 are nominal output current of 17.5 A and an adjustable switching frequency ranging from 2...16 kHz adjustable4...16 kHz with derating factor, this sensor ensures optimal performance in various environments. The power factor is 0.615 at 230 V, contributing to its energy efficiency. Electrical connections are made via Screw terminal, clamping capacity: 0.5...1.5 mm² for analog inputScrew terminal for analog outputScrew terminal. It operates in a vertical position with a tolerance of Vertical +/- 10 degree, making it flexible for different mounting scenarios. The sensor’s width is compact at 140 mm, and it supports a maximum input current of 23.8 A. The maximum output voltage is 240 V, with a network frequency of 50...60 Hz. Designed for Wall mount, it has a cooling air volume of 16.4 m3/h. The product belongs to the Altivar Solar range. It's Time to get a Quote for your requirement of Schneider Altivar Solar 4.0kW VSD. We guarantee unmatched pricing and unparalleled support compared to other Distributors.