ATV320U40M3C412: Schneider Altivar Solar 4.0kW VSD
technical Specifications of Schneider Altivar Solar 4.0kW VSD ATV320U40M3C412:
Spec | Value |
---|---|
Nominal output current | 17.5 A |
Switching frequency | 2...16 kHz adjustable4...16 kHz with derating factor |
Power factor | 0.615 at 230 V |
Electrical connection | Screw terminal, clamping capacity: 0.5...1.5 mm² for analog inputScrew terminal for analog outputScrew terminal |
Schneider Altivar Solar 4.0kW VSD ATV320U40M3C412 Technical Specifications:
Specification | Value |
---|---|
Analogue input number | 3 |
With safety function Safe Speed Monitor (SSM) | FALSE |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
Number of Units in Package 2 | 12 |
Ambient air temperature for operation | -10…50 °C without derating50…60 °C with derating factor |
Nominal output current | 17.5 A |
Format of the drive | Compact |
Local signalling | 1 LED (red) for drive fault1 LED (red) for CANopen error1 LED (green) for CANopen run |
Minimum switching current | Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC |
Switching frequency | 2...16 kHz adjustable4...16 kHz with derating factor |
Acceleration and deceleration ramps | LinearUSCUSRamp switchingAcceleration/deceleration ramp adaptationAcceleration/deceleration automatic stop with DC injectionAutomatic adaptation of ramp if braking capacity exceeded, by using resistorLinear adjustable separately from 0.01 to 6000 s |
Discrete input type | STO safe torque off, 24 V DC, impedance: 1.5 kOhmDI1...DI6 logic inputs, 24 V DC (30 V)DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V) |
Analogue output type | Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bitsSoftware-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
Base load current at high overload | 17.0 A |
Discrete input logic | Positive logic (source)Negative logic (sink) |
Data format | 8 bits, configurable odd, even or no parity |
With sft fct Safe Stop 2 (SS2) | FALSE |
Power factor | 0.615 at 230 V |
Communication port protocol | Modbus serialCANopen |
Package 2 Height | 75 cm |
Unit Type of Package 2 | S06 |
Electrical connection | Screw terminal, clamping capacity: 0.5...1.5 mm² for analog inputScrew terminal for analog outputScrew terminal |
Operating position | Vertical +/- 10 degree |
Width | 140 mm |
Package 1 Height | 24.5 cm |
Power dissipation in W | Fan: 140 W at 200 V, switching frequency 4 kHz |
Maximum input current | 23.8 A |
Package 1 Length | 26.8 cm |
Assembly style | With heat sink |
Braking torque | 170 % with braking resistor |
Overvoltage category | II |
Prospective line Isc | 5 kA |
Depth | 158.0 mm |
Short-circuit protection | thermal protection |
4 quadrant operation possible | TRUE |
Package 1 Weight | 2.605 kg |
With safety function Safe Direction (SDI) | FALSE |
Motor power kW | 4.0 kW for heavy duty |
Transient overtorque | 170…200 % of nominal motor torque |
Package 1 Width | 19.1 cm |
Package 2 Length | 80 cm |
Net Weight | 2.2 kg |
Number of Units in Package 1 | 1 |
Discrete output type | Open collector DQ+ 0…1 kHz 30 V DC 100 mAOpen collector DQ- 0…1 kHz 30 V DC 100 mA |
Analogue input type | AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bitsAI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bitsAI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits |
Maximum output voltage | 240 V |
Apparent power | 8.3 kVA at 240 V (heavy duty) |
Ambient air temperature for storage | -25…70 °C |
Mounting mode | Wall mount |
Maximum switching current | Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DCRelay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V ACRelay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC |
Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
Protection type | Input phase breaks: driveOvercurrent between output phases and earth: driveOverheating protection: driveShort-circuit between motor phases: driveThermal protection: drive |
Range of product | Altivar Solar |
Relay output number | 2 |
[Us] rated supply voltage | 200...240 V - 15...10 % |
EMC filter | Without EMC filter |
Ambient air transport temperature | -25…70 °C |
Nominal switching frequency | 4 kHz |
IP degree of protection | IP20 |
Get A Quote for Schneider Altivar Solar 4.0kW VSD ATV320U40M3C412 at the best price. Here are the brief Technical Specifications of ATV320U40M3C412 are nominal output current of 17.5 A and an adjustable switching frequency ranging from 2...16 kHz adjustable4...16 kHz with derating factor, this sensor ensures optimal performance in various environments. The power factor is 0.615 at 230 V, contributing to its energy efficiency. Electrical connections are made via Screw terminal, clamping capacity: 0.5...1.5 mm² for analog inputScrew terminal for analog outputScrew terminal. It operates in a vertical position with a tolerance of Vertical +/- 10 degree, making it flexible for different mounting scenarios. The sensor’s width is compact at 140 mm, and it supports a maximum input current of 23.8 A. The maximum output voltage is 240 V, with a network frequency of 50...60 Hz. Designed for Wall mount, it has a cooling air volume of 16.4 m3/h. The product belongs to the Altivar Solar range. It's Time to get a Quote for your requirement of Schneider Altivar Solar 4.0kW VSD. We guarantee unmatched pricing and unparalleled support compared to other Distributors.