Shock Resistance15 gn for 11 ms conforming to IEC 60068-2-27
Connection TypeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCPRJ45 (on the remote graphic terminal) for Modbus serial
Motor Power KW75 kW (normal duty)55 kW (heavy duty)
Switching Frequency2.5...8 kHz with derating factor2...8 kHz adjustable

100 HP VFD Schneider ATV630D75N4Z Technical Specifications:

SpecificationValue
Maximum input current131.3 A
Electrical connectionControl: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16Motor: screw terminal 95...120 mm²/AWG 3/0...250 kcmilLine side: screw terminal 95...120 mm²/AWG 3/0...250 kcmil
Power dissipation in WNatural convection: 174 W at 380 V, switching frequency 2.5 kHzForced convection: 1369 W at 380 V, switching frequency 2.5 kHz
Overvoltage categoryIII
Net weight54.1 kg
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Frequency resolutionDisplay unit: 0.1 HzAnalog input: 0.012/50 Hz
Output voltage<= power supply voltage
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Product or component typeVariable speed drive
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mARelay outputs R1A, R1B, R1C 30 V DC 3000 mARelay outputs R2A, R2C 250 V AC 5000 mARelay outputs R2A, R2C 30 V DC 5000 mARelay outputs R3A, R3C 250 V AC 5000 mARelay outputs R3A, R3C 30 V DC 5000 mA
Nominal switching frequency2.5 kHz
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protectionInternal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Maximum transient current159.5 A during 60 s (normal duty)159 A during 60 s (heavy duty)
Relay output number3
Type of polarizationNo impedance
Product specific applicationProcess and utilities
Volume of cooling air295 m3/h
Connector typeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCPRJ45 (on the remote graphic terminal) for Modbus serial
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Method of accessSlave Modbus TCP
Product destinationAsynchronous motorsSynchronous motors
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Ambient air temperature for storage-40…70 °C
Motor power hp100 hp normal duty75 hp heavy duty
Transmission rate10, 100 Mbits4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Maximum THDI<48 % from 80...100 % of load conforming to IEC 61000-3-12
Height748 mm
Type of coolingForced convection
Motor power kW75 kW (normal duty)55 kW (heavy duty)
Number of Units in Package 11
Physical interfaceEthernet2-wire RS 485
Switching frequency2.5...8 kHz with derating factor2...8 kHz adjustable
Apparent power93.7 kVA at 480 V (normal duty)72.2 kVA at 480 V (heavy duty)
StandardsUL 508CIEC 61800-3IEC 61800-3 environment 1 category C2EN/IEC 61800-3 environment 2 category C3IEC 61800-5-1IEC 61000-3-12IEC 60721-3IEC 61508IEC 13849-1
Operating positionVertical +/- 10 degree
Discrete input logicPositive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Package 2 Length-
Range of productAltivar Process ATV600
[Us] rated supply voltage380...480 V - 15...10 %
Permissible temporary current boost1.1 x In during 60 s (normal duty)1.5 x In during 60 s (heavy duty)
MarkingCE
Analogue input number3
Asynchronous motor control profileVariable torque standardConstant torque standardOptimized torque mode
Enclosure mountingWith heat sink
IsolationBetween power and control terminals
Ambient air temperature for operation-15…50 °C (without derating)50…60 °C (with derating factor)
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-61 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Supply frequency50...60 Hz - 5...5 %
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Analogue output number2
Pollution degree2
Email us for your 100 HP Schneider VFD ATV630D75N4Z needs at budget-friendly prices. This model, part of the Altivar Process ATV600 range, is engineered for process and utility applications. Key technical parameters include a maximum input current of 131.3 A, with a frequency resolution of 0.1 Hz on the display unit and 0.012/50 Hz on the analog input. The output voltage is up to the power supply voltage, with a maximum transient current of 159.5 A for 60 seconds in normal duty and 159 A for heavy duty. It supports motor power of 100 hp in normal duty and 75 hp in heavy duty, with a height of 748 mm and connectivity options that include Ethernet and 2-wire RS 485. The switching frequency is adjustable from 2...8 kHz or 2.5...8 kHz with a derating factor. Operating at a rated supply voltage [Us] of 380...480 V, with a tolerance of -15...+10 %, and a supply frequency of 50...60 Hz within -5...+5 % tolerance, it offers a maximum output frequency of 500 kHz and a secure cabinet mount. Contact us for a customized quote on the Schneider 100 HP VFD and discover our competitive pricing and exceptional support that outshines other suppliers.