ATV630D90N4Z | Schneider Altivar Process ATV600 90kW VSD
+91 79955 44066 sales@indmall.in

ATV630D90N4Z: Schneider Altivar Process ATV600 90kW VSD

Technical Specifications of Schneider Altivar Process ATV600 90kW VSD ATV630D90N4Z:

SpecValue
Shock Resistance15 gn for 11 ms conforming to IEC 60068-2-27
Connection TypeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCPRJ45 (on the remote graphic terminal) for Modbus serial
Motor Power KW90 kW (normal duty)75 kW (heavy duty)
Switching Frequency2.5...8 kHz with derating factor2...8 kHz adjustable

Schneider Altivar Process ATV600 90kW VSD ATV630D90N4Z Technical Specifications:

SpecificationValue
Maximum input current156.2 A
Electrical connectionControl: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16Line side: screw terminal 120 mm²/AWG 4/0...250 kcmilMotor: screw terminal 120 mm²/250 kcmil
Power dissipation in WNatural convection: 196 W at 380 V, switching frequency 2.5 kHzForced convection: 1585 W at 380 V, switching frequency 2.5 kHz
Overvoltage categoryIII
Net weight54.6 kg
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Frequency resolutionDisplay unit: 0.1 HzAnalog input: 0.012/50 Hz
Output voltage<= power supply voltage
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Product or component typeVariable speed drive
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mARelay outputs R1A, R1B, R1C 30 V DC 3000 mARelay outputs R2A, R2C 250 V AC 5000 mARelay outputs R2A, R2C 30 V DC 5000 mARelay outputs R3A, R3C 250 V AC 5000 mARelay outputs R3A, R3C 30 V DC 5000 mA
Nominal switching frequency2.5 kHz
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protectionInternal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Maximum transient current190.3 A during 60 s (normal duty)217.5 A during 60 s (heavy duty)
Relay output number3
Type of polarizationNo impedance
Product specific applicationProcess and utilities
Volume of cooling air295 m3/h
Connector typeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCPRJ45 (on the remote graphic terminal) for Modbus serial
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Method of accessSlave Modbus TCP
Product destinationAsynchronous motorsSynchronous motors
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Ambient air temperature for storage-40…70 °C
Motor power hp125 hp normal duty100 hp heavy duty
Transmission rate10, 100 Mbits4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Maximum THDI<48 % from 80...100 % of load conforming to IEC 61000-3-12
Height748 mm
Type of coolingForced convection
Motor power kW90 kW (normal duty)75 kW (heavy duty)
Number of Units in Package 11
Physical interfaceEthernet2-wire RS 485
Switching frequency2.5...8 kHz with derating factor2...8 kHz adjustable
Apparent power112.9 kVA at 480 V (normal duty)98.2 kVA at 480 V (heavy duty)
StandardsUL 508CIEC 61800-3IEC 61800-3 environment 1 category C2EN/IEC 61800-3 environment 2 category C3IEC 61800-5-1IEC 61000-3-12IEC 60721-3IEC 61508IEC 13849-1
Operating positionVertical +/- 10 degree
Discrete input logicPositive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Package 2 Length-
Range of productAltivar Process ATV600
[Us] rated supply voltage380...480 V - 15...10 %
Permissible temporary current boost1.1 x In during 60 s (normal duty)1.5 x In during 60 s (heavy duty)
MarkingCE
Analogue input number3
Asynchronous motor control profileConstant torque standardVariable torque standardOptimized torque mode
Enclosure mountingWith heat sink
IsolationBetween power and control terminals
Ambient air temperature for operation-15…50 °C (without derating)50…60 °C (with derating factor)
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-61 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Supply frequency50...60 Hz - 5...5 %
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Analogue output number2
Pollution degree2
Obtain a Quote for Schneider Altivar Process ATV600 90kW VSD ATV630D90N4Z at economical prices. Specifications Overview for ATV630D90N4Z reveals Altivar Process ATV600 range, designed for Process and utilities applications. It has a maximum input current of 156.2 A, with a frequency resolution of Display unit: 0.1 HzAnalog input: 0.012/50 Hz. The output voltage is equal to or less than the <= power supply voltage, while the maximum transient current reaches 190.3 A during 60 s (normal duty)217.5 A during 60 s (heavy duty) operations. The sensor features a motor power of 125 hp normal duty100 hp heavy duty. Its height is 748 mm, and the physical interface includes Ethernet2-wire RS 485. The switching frequency is 2.5...8 kHz with derating factor2...8 kHz adjustable. It operates at a rated supply voltage [Us] of 380...480 V - 15...10 % with a supply frequency of 50...60 Hz - 5...5 %. The maximum output frequency is 500 kHz, with a Cabinet mount mode for secure installation. Take the First Step with a Quote for your requirement of Schneider Altivar Process ATV600 90kW VSD. Our commitment to better pricing and exceptional support sets us apart from other Competitors.