ATV630U15N4Z | 1.5 KW VFD Schneider
+91 79955 44066 sales@indmall.in

ATV630U15N4Z: 1.5 KW VFD Schneider

Technical Specifications of 1.5 KW VFD Schneider ATV630U15N4Z:

SpecValue
Shock Resistance15 gn for 11 ms conforming to IEC 60068-2-27
Connection TypeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCPRJ45 (on the remote graphic terminal) for Modbus serial
Motor Power KW1.5 kW (normal duty)0.75 kW (heavy duty)
Switching Frequency2...12 kHz adjustable4...12 kHz with derating factor

1.5 KW VFD Schneider ATV630U15N4Z Technical Specifications:

SpecificationValue
Maximum input current3.0 A
Electrical connectionControl: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16Motor: screw terminal 2.5...6 mm²/AWG 14...AWG 10Line side: screw terminal 2.5...6 mm²/AWG 14...AWG 10
Power dissipation in WNatural convection: 28 W at 380 V, switching frequency 4 kHzForced convection: 41 W at 380 V, switching frequency 4 kHz
Overvoltage categoryIII
Net weight3.7 kg
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Frequency resolutionDisplay unit: 0.1 HzAnalog input: 0.012/50 Hz
Output voltage<= power supply voltage
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Product or component typeVariable speed drive
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mARelay outputs R1A, R1B, R1C 30 V DC 3000 mARelay outputs R2A, R2C 250 V AC 5000 mARelay outputs R2A, R2C 30 V DC 5000 mARelay outputs R3A, R3C 250 V AC 5000 mARelay outputs R3A, R3C 30 V DC 5000 mA
Nominal switching frequency4 kHz
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protectionInternal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Maximum transient current4.4 A during 60 s (normal duty)3.3 A during 60 s (heavy duty)
Relay output number3
Type of polarizationNo impedance
Product specific applicationProcess and utilities
Volume of cooling air38 m3/h
Connector typeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCPRJ45 (on the remote graphic terminal) for Modbus serial
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Method of accessSlave Modbus TCP
Product destinationAsynchronous motorsSynchronous motors
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Ambient air temperature for storage-40…70 °C
Motor power hp2 hp normal duty1 hp heavy duty
Transmission rate10, 100 Mbits4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Maximum THDI<48 % full load conforming to IEC 61000-3-12
Height285 mm
Type of coolingForced convection
Motor power kW1.5 kW (normal duty)0.75 kW (heavy duty)
Number of Units in Package 11
Physical interfaceEthernet2-wire RS 485
Switching frequency2...12 kHz adjustable4...12 kHz with derating factor
Apparent power2.2 kVA at 480 V (normal duty)1.2 kVA at 480 V (heavy duty)
StandardsUL 508CIEC 61800-3IEC 61800-3 environment 1 category C2EN/IEC 61800-3 environment 2 category C3IEC 61800-5-1IEC 61000-3-12IEC 60721-3IEC 61508IEC 13849-1
Operating positionVertical +/- 10 degree
Discrete input logicPositive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Package 2 Length60.0 cm
Range of productAltivar Process ATV600
[Us] rated supply voltage380...480 V - 15...10 %
Permissible temporary current boost1.1 x In during 60 s (normal duty)1.5 x In during 60 s (heavy duty)
MarkingCE
Analogue input number3
Asynchronous motor control profileVariable torque standardConstant torque standardOptimized torque mode
Enclosure mountingWith heat sink
IsolationBetween power and control terminals
Ambient air temperature for operation-15…50 °C (without derating)50…60 °C (with derating factor)
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-61 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Supply frequency50...60 Hz - 5...5 %
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Analogue output number2
Pollution degree2
Request unbeatable pricing on the 1.5 KW Schneider VFD ATV630U15N4Z. Detailed specifications of the ATV630U15N4Z include its Altivar Process ATV600 range, designed specifically for process and utility applications. It supports a maximum input current of 3.0 A, with a frequency resolution of 0.1 Hz on the display unit and 0.012/50 Hz on analog input. The output voltage matches or stays below the power supply voltage, with maximum transient currents reaching 4.4 A for 60 seconds in normal duty and 3.3 A for 60 seconds in heavy duty. This model has a motor power of 2 hp for normal duty and 1 hp for heavy duty. Measuring 285 mm in height, it includes Ethernet and a 2-wire RS 485 interface. The switching frequency is adjustable from 2...12 kHz or 4...12 kHz with a derating factor, operating on a rated supply voltage [Us] of 380...480 V with a tolerance of -15...+10 % and a supply frequency of 50...60 Hz with -5...+5 % tolerance. With a maximum output frequency of 500 kHz and a cabinet mount for secure installation, this VFD is optimized for demanding applications. Now’s the time to request your customized quote for the 1.5 KW Schneider VFD. Enjoy our competitive pricing and attentive support that outperforms other traders.