Technical Specifications of Schneider 240 VAC 4 NO Control Relay CAE40U5:

SpecValue
Productor Component TypeControl relay
Control Circuit TypeAC at 50 Hz
Mounting SupportPlateRail
Inrush power in VA70 VA 50 Hz (at 20 °C)

Schneider 240 VAC 4 NO Control Relay CAE40U5 Technical Specifications:

SpecificationValue
RangeEasy TeSys
Product or component typeControl relay
Device short nameCAE
Contactor ApplicationControl circuit
ColourGrey (RAL 7011)
Pole contact composition4 NO
[Ue] rated operational voltage<= 690 V AC
Control circuit typeAC at 50 Hz
[Uc] control circuit voltage240 V AC 50 Hz
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Operating Altitude3000 m without derating
[Ith] conventional free air thermal current10 A (at 40 °C)
Irms rated making capacity140 A at 690 V AC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current120 A - 500 ms140 A - 100 ms
Associated fuse rating10 A gG at 690 V conforming to IEC 60947-5-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-5-1
Mounting SupportPlateRail
Connections - terminalsScrew clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable endScrew clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable endScrew clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endScrew clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable endScrew clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end
Recommended tightening torque1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit voltage limitsOperational: 0.85...1.1 Uc at 50 HzDrop-out: 0.3...0.6 Uc
Operating time12...22 ms coil energisation and NO closing6...17 ms coil de-energisation and NO closing
Inrush power in VA70 VA 50 Hz (at 20 °C)
Hold-in power consumption in VA8 VA 50 Hz (at 20 °C)
Minimum switching voltage17 V
Minimum switching current5 mA
Insulation resistance> 10 MOhm
Height74 mm
Width45 mm
Depth80 mm
Net weight0.28 kg
IP degree of protectionIP2X conforming to IEC 60529
Ambient air temperature for operation-20…70 °C
Ambient air temperature for storage-60…80 °C
Operating altitude3000 m without derating
Ask for the Pricing of Schneider 240 VAC 4 NO Control Relay CAE40U5 at unbeatable prices. Detailed Specifications of CAE40U5 features Easy TeSys Control Relay, Range of product. This Control relay features a pole contact composition of 4 NO and operates with an operational voltage of up to <= 690 V AC, making it ideal for a wide range of industrial applications. It supports a AC at 50 Hz control circuit with a control circuit voltage of 240 V AC 50 Hz. The relay’s rated impulse withstand voltage is 6 kV conforming to IEC 60947 standards. Inrush power consumption is 70 VA 50 Hz (at 20 °C), with hold-in power consumption at 8 VA 50 Hz (at 20 °C). The minimum switching voltage is 17 V, and the minimum switching current is 5 mA. Now's the Time to Secure a Quote for your requirement of Schneider 240 VAC 4 NO Control Relay. We're committed to offering more favorable pricing and more responsive support than other Traders.