GZ1E14 | Schneider GZ1 Breaker 6-10A Thermomagnetic
+91 79955 44066 sales@indmall.in

GZ1E14: Schneider GZ1 Breaker 6-10A Thermomagnetic

Technical Specifications of Schneider GZ1 Breaker 6-10A Thermomagnetic GZ1E14:

SpecValue
Mounting SupportRail
Power Dissipation2.5 W (per pole)
Mounting ModeBy clipsBy screws
Connections TerminalsScrew clamp terminals 2 1…6 mm² - cable stiffness: solidScrew clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end

Schneider GZ1 Breaker 6-10A Thermomagnetic GZ1E14 Technical Specifications:

SpecificationValue
Device applicationMotor
mounting positionAny position
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Ambient air temperature for operation-20…60 °C
Mounting supportRail
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Electrical durability100000 cycles for AC-3
RangeEasy TeSys
Magnetic tripping current138 A
Product or component typeCircuit breaker
poles description3P
Width44.5 mm
Control typePush-button
IP degree of protectionIP20 conforming to IEC 60529
ColourGrey (RAL 7011)
Power dissipation2.5 W (per pole)
mounting modeBy clipsBy screws
Operating altitude2000 m
Fire resistance960 °C conforming to IEC 60695-2-1
Thermal protection adjustment range6…10 A
Net weight0.26 kg
Motor power kW2.2 kW at 230 V AC 50/60 Hz4 kW at 400 V AC 50/60 Hz4 kW at 440 V AC 50/60 Hz5.5 kW at 500 V AC 50/60 Hz7.5 kW at 690 V AC 50/60 Hz
Network typeAC
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Device short nameGZ1E
Utilisation categoryAC-3
Maximum operating rate25 cyc/h
Range of productEasy TeSys Power
Ambient air temperature for storage-40…80 °C
Network frequency50/60 Hz conforming to IEC 60947-2
Depth78 mm
Trip unit technologyThermal-magnetic
Height89 mm
Connections - terminalsScrew clamp terminals 2 1…6 mm² - cable stiffness: solidScrew clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end
Ask for the Pricing of Schneider GZ1 Breaker 6-10A Thermomagnetic GZ1E14 at unbeatable prices. Detailed Specifications of GZ1E14 features Motor applications, suitable for installation in Any position. It has a rated impulse to withstand voltage [Uimp] of 6 kV conforming to IEC 60947-2 standards, ensuring robust protection. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C and can be mounted on a Rail for flexible installation. Its rated operational voltage [Ue] is 690 V AC 50/60 Hz conforming to IEC 60947-2, providing reliable power handling. With the electrical durability of 100000 cycles for AC-3 applications, this sensor ensures long-lasting performance. The magnetic tripping current is set at 138 A, and it features a 3P configuration. Now's the Time to Secure a Quote for your requirement of Schneider GZ1 Breaker 6-10A Thermomagnetic. We're committed to offering more favorable pricing and more responsive support than other Traders.