LC1E120M5: Schneider Easy TeSys Contactor 3P 120A 220V AC
Technical Specifications of Schneider Easy TeSys Contactor 3P 120A 220V AC LC1E120M5:
Spec | Value |
---|---|
Product Component Type | Contactor |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
Power Dissipation Per Pole | 8.6 W AC-314 W AC-1 |
Tightening Torque | Power circuit: 12 N.mControl circuit: 1.2 N.m |
Schneider Easy TeSys Contactor 3P 120A 220V AC LC1E120M5 Technical Specifications:
Specification | Value |
---|---|
Range | Easy TeSys |
Range of product | Easy TeSys Control |
Product or component type | Contactor |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current | 120 A (at <55 °C) at <= 440 V AC AC-3 for power circuit150 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 220 V AC 50 Hz |
Motor power kW | 37 kW at 220...230 V AC 50/60 Hz (AC-3)55 kW at 380...400 V AC 50/60 Hz (AC-3)59 kW at 415 V AC 50/60 Hz (AC-3)59 kW at 440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 660...690 V AC 50/60 Hz (AC-3) |
Pole contact composition | 3 NO |
[Ith] conventional free air thermal current | 150 A (at 40 °C) |
Irms rated making capacity | 1200 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 960 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 1100 A 40 °C - 10 s for power circuit |
Associated fuse rating | 250 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-110 A gG at <= 690 V coordination type 1 for power circuit |
Power dissipation per pole | 8.6 W AC-314 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
[Uimp] rated impulse withstand voltage | 8 kV coil not connected to the power circuit conforming to IEC 60947 |
Control circuit type | AC at 50 Hz |
Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50 Hz0.35...0.55 Uc (-5…55 °C):drop-out 50 Hz |
Inrush power in VA | 300 VA 50 Hz cos phi 0.8 (at 20 °C)300 VA 60 Hz cos phi 0.8 (at 20 °C) |
Hold-in power consumption in VA | 22 VA 50 Hz cos phi 0.3 (at 20 °C)22 VA 60 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 3…8 W for control circuit |
Operating time | 20...50 ms on closing6...20 ms on opening |
Maximum operating rate | 1200 cyc/h 55 °C |
Connections - terminals | Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 20…170 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 20…170 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end |
Tightening torque | Power circuit: 12 N.mControl circuit: 1.2 N.m |
Auxiliary contact composition | 1 NO + 1 NC |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Mounting support | DIN railPlate |
IP degree of protection | IP2X conforming to IEC 60529 |
Height | 158 mm |
Width | 120 mm |
Depth | 132 mm |
Net weight | 2.3 kg |
Obtain a Quote for Schneider Easy TeSys Contactor 3P 120A 220V AC LC1E120M5 at economical prices. Specifications Overview for LC1E120M5 reveals Easy TeSys Control Range of products and the Contactor Product or component type 3P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 120 A (at <55 °C) at <= 440 V AC AC-3 for power circuit150 A (at <55 °C) at <= 440 V AC AC-1 for power circuit. It operates at a control circuit voltage of 220 V AC 50 Hz, with 3 NO poles. Take the First Step with a Quote for your requirement of Schneider Easy TeSys Contactor 3P 120A 220V AC. Our commitment to better pricing and exceptional support sets us apart from other Competitors.