Technical Specifications of Schneider 18A Easy TeSys 240V AC 3P Contactor LC1E1810U5:

SpecValue
Product Component TypeContactor
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
Power Dissipation Per Pole0.81 W AC-32.6 W AC-1
Tightening TorquePower circuit: 1.2 N.mControl circuit: 1.2 N.m

Schneider 18A Easy TeSys 240V AC 3P Contactor LC1E1810U5 Technical Specifications:

SpecificationValue
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current32 A (at <55 °C) at <= 415 V AC AC-1 for power circuit18 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
[Uc] control circuit voltage240 V AC 50 Hz
Motor power kW4 kW at 220...230 V AC 50/60 Hz (AC-3)7.5 kW at 380...400 V AC 50/60 Hz (AC-3)9 kW at 415 V AC 50/60 Hz (AC-3)9 kW at 440 V AC 50/60 Hz (AC-3)10 kW at 500 V AC 50/60 Hz (AC-3)10 kW at 660...690 V AC 50/60 Hz (AC-3)
Pole contact composition3 NO
[Ith] conventional free air thermal current32 A (at 55 °C)
Irms rated making capacity180 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity144 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current145 A 40 °C - 10 s for power circuit84 A 40 °C - 60 s for power circuit40 A 40 °C - 600 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-135 A gG at <= 690 V coordination type 1 for power circuit
Power dissipation per pole0.81 W AC-32.6 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50 Hz0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C)95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA8.3 VA 50 Hz cos phi 0.3 (at 20 °C)8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W for control circuit
Operating time12...22 ms on closing4...19 ms on opening
Maximum operating rate1800 cyc/h 60 °C
Connections - terminalsPower circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end
Tightening torquePower circuit: 1.2 N.mControl circuit: 1.2 N.m
Auxiliary contact composition1 NO
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Mounting supportPlateDIN rail
IP degree of protectionIP2X conforming to IEC 60529
Height74 mm
Width45 mm
Depth80 mm
Net weight0.3 kg
Send Your Inquiry for Schneider 18A Easy TeSys 240V AC 3P Contactor LC1E1810U5 with cost-effective solutions. Essential Technical Specs of LC1E1810U5 are Easy TeSys Control Range of products and the Contactor Product or component type 3P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 32 A (at <55 °C) at <= 415 V AC AC-1 for power circuit18 A (at <55 °C) at <= 440 V AC AC-3 for power circuit. It operates at a control circuit voltage of 240 V AC 50 Hz, with 3 NO poles. The conventional free air thermal current is rated at 32 A (at 55 °C), and power dissipation per pole is 0.81 W AC-32.6 W AC-1. The rated insulation voltage is 690 V conforming to IEC 60947-4-1, and the impulse withstand voltage is 6 kV coil not connected to the power circuit conforming to IEC 60947. Capture the Best Deal with a Quote for your requirement of Schneider 18A Easy TeSys 240V AC 3P Contactor. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.