LC1E2510F7: Schneider Easy TeSys 25A 110V AC 3P Contactor
Technical Specifications of Schneider Easy TeSys 25A 110V AC 3P Contactor LC1E2510F7:
Spec | Value |
---|---|
Product Component Type | Contactor |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
Power Dissipation Per Pole | 1.6 W AC-33.2 W AC-1 |
Tightening Torque | Control circuit: 1.2 N.mPower circuit: 1.5 N.m |
Schneider Easy TeSys 25A 110V AC 3P Contactor LC1E2510F7 Technical Specifications:
Specification | Value |
---|---|
Range | Easy TeSys |
Range of product | Easy TeSys Control |
Product or component type | Contactor |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current | 25 A (at <55 °C) at <= 440 V AC AC-3 for power circuit36 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 110 V AC 50/60 Hz |
Motor power kW | 5.5 kW at 220...230 V AC 50/60 Hz11 kW at 380...400 V11 kW at 415 V11 kW at 440 V15 kW at 500 V15 kW at 660...690 V |
Pole contact composition | 3 NO |
[Ith] conventional free air thermal current | 36 A (at 55 °C) |
Irms rated making capacity | 250 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 200 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 240 A 40 °C - 10 s for power circuit120 A 40 °C - 60 s for power circuit50 A 40 °C - 600 s for power circuit |
Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-140 A gG at <= 690 V coordination type 1 for power circuit |
Power dissipation per pole | 1.6 W AC-33.2 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
Control circuit type | AC at 50/60 Hz |
Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50/60 Hz0.3...0.6 Uc (-5…55 °C):drop-out 50/60 Hz |
Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C)95 VA 60 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C)8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 2…3 W for control circuit |
Operating time | 12...22 ms on closing4...19 ms on opening |
Maximum operating rate | 1800 cyc/h 60 °C |
Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end |
Tightening torque | Control circuit: 1.2 N.mPower circuit: 1.5 N.m |
Auxiliary contact composition | 1 NO |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Mounting support | PlateDIN rail |
IP degree of protection | IP2X conforming to IEC 60529 |
Height | 74 mm |
Width | 45 mm |
Depth | 85 mm |
Net weight | 0.36 kg |
Ask for the Pricing of Schneider Easy TeSys 25A 110V AC 3P Contactor LC1E2510F7 at unbeatable prices. Detailed Specifications of LC1E2510F7 features Easy TeSys Control Range of products and the Contactor Product or component type 3P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 25 A (at <55 °C) at <= 440 V AC AC-3 for power circuit36 A (at <55 °C) at <= 440 V AC AC-1 for power circuit. It operates at a control circuit voltage of 110 V AC 50/60 Hz, with 3 NO poles. The conventional free air thermal current is rated at 36 A (at 55 °C), and power dissipation per pole is 1.6 W AC-33.2 W AC-1. The rated insulation voltage is 690 V conforming to IEC 60947-4-1, and the impulse withstand voltage is 6 kV coil not connected to the power circuit conforming to IEC 60947. Now's the Time to Secure a Quote for your requirement of Schneider Easy TeSys 25A 110V AC 3P Contactor. We're committed to offering more favorable pricing and more responsive support than other Traders.