LC1E3210Q7 | Schneider Easy TeSys Contactor 3P 32A 380V AC
+91 79955 44066 sales@indmall.in

LC1E3210Q7: Schneider Easy TeSys Contactor 3P 32A 380V AC

Technical Specifications of Schneider Easy TeSys Contactor 3P 32A 380V AC LC1E3210Q7:

SpecValue
Product Component TypeContactor
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
Power Dissipation Per Pole2 W AC-35 W AC-1
Tightening TorqueControl circuit: 1.2 N.mPower circuit: 2.1 N.m

Schneider Easy TeSys Contactor 3P 32A 380V AC LC1E3210Q7 Technical Specifications:

SpecificationValue
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage380 V AC 50/60 Hz
Motor power kW7.5 kW at 220...230 V AC 50/60 Hz15 kW at 380...400 V15 kW at 415 V15 kW at 440 V18.5 kW at 500 V18.5 kW at 660...690 V
Pole contact composition3 NO
[Ith] conventional free air thermal current50 A (at 55 °C)
Irms rated making capacity320 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity256 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current260 A 40 °C - 10 s for power circuit138 A 40 °C - 60 s for power circuit60 A 40 °C - 600 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-163 A gG at <= 690 V coordination type 1 for power circuit
Power dissipation per pole2 W AC-35 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Control circuit typeAC at 50/60 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50/60 Hz0.3...0.6 Uc (-5…55 °C):drop-out 50/60 Hz
Inrush power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C)95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA8.3 VA 50 Hz cos phi 0.3 (at 20 °C)8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W for control circuit
Operating time12...22 ms on closing4...19 ms on opening
Maximum operating rate1800 cyc/h 60 °C
Connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end
Tightening torqueControl circuit: 1.2 N.mPower circuit: 2.1 N.m
Auxiliary contact composition1 NO
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Mounting supportDIN railPlate
IP degree of protectionIP2X conforming to IEC 60529
Height84 mm
Width56 mm
Depth86 mm
Net weight0.45 kg
Call us for Schneider Easy TeSys Contactor 3P 32A 380V AC LC1E3210Q7 at the best rates. Technical Attributes of LC1E3210Q7 are Easy TeSys Control Range of products and the Contactor Product or component type 3P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit. It operates at a control circuit voltage of 380 V AC 50/60 Hz, with 3 NO poles. The conventional free air thermal current is rated at 50 A (at 55 °C), and power dissipation per pole is 2 W AC-35 W AC-1. The rated insulation voltage is 690 V conforming to IEC 60947-4-1, and the impulse withstand voltage is 6 kV coil not connected to the power circuit conforming to IEC 60947. Unlock Exclusive Pricing with a Quote for your requirement of Schneider Easy TeSys Contactor 3P 32A 380V AC. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.