LC1E40M7 | Schneider Easy TeSys Contactor 3P 40A 220V AC
+91 79955 44066 sales@indmall.in

LC1E40M7: Schneider Easy TeSys Contactor 3P 40A 220V AC

Technical Specifications of Schneider Easy TeSys Contactor 3P 40A 220V AC LC1E40M7:

SpecValue
Product Component TypeContactor
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
Power Dissipation Per Pole2.4 W AC-35.4 W AC-1
Tightening TorqueControl circuit: 1.2 N.mPower circuit: 5 N.m

Schneider Easy TeSys Contactor 3P 40A 220V AC LC1E40M7 Technical Specifications:

SpecificationValue
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current40 A (at <55 °C) at <= 440 V AC AC-3 for power circuit60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Motor power kW18.5 kW at 380...400 V11 kW at 220...230 V AC 50/60 Hz22 kW at 415 V22 kW at 440 V22 kW at 500 V30 kW at 660...690 V
Pole contact composition3 NO
[Ith] conventional free air thermal current60 A (at 55 °C)
Irms rated making capacity400 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity320 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 40 °C - 10 s for power circuit165 A 40 °C - 60 s for power circuit72 A 40 °C - 600 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-180 A gG at <= 690 V coordination type 1 for power circuit
Power dissipation per pole2.4 W AC-35.4 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Control circuit typeAC at 50/60 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50/60 Hz0.3...0.6 Uc (-5…55 °C):drop-out 50/60 Hz
Inrush power in VA160 VA 50 Hz cos phi 0.75 (at 20 °C)140 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA15 VA 50 Hz cos phi 0.3 (at 20 °C)13 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation6…10 W for control circuit
Operating time20...26 ms on closing8...12 ms on opening
Maximum operating rate1200 cyc/h 55 °C
Connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.mPower circuit: 5 N.m
Auxiliary contact composition1 NO + 1 NC
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Mounting supportPlateDIN rail
IP degree of protectionIP2X conforming to IEC 60529
Height127 mm
Width75 mm
Depth114 mm
Net weight0.98 kg
Please speak to our Technical Engineer for Schneider Easy TeSys Contactor 3P 40A 220V AC LC1E40M7 at attractive prices. Technical Specs Summary of LC1E40M7 includes Easy TeSys Control Range of products and the Contactor Product or component type 3P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 40 A (at <55 °C) at <= 440 V AC AC-3 for power circuit60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit. It operates at a control circuit voltage of 220 V AC 50/60 Hz, with 3 NO poles. The conventional free air thermal current is rated at 60 A (at 55 °C), and power dissipation per pole is 2.4 W AC-35.4 W AC-1. The rated insulation voltage is 690 V conforming to IEC 60947-4-1, and the impulse withstand voltage is 6 kV coil not connected to the power circuit conforming to IEC 60947. Match Your Needs with a Quote for your requirement of Schneider Easy TeSys Contactor 3P 40A 220V AC. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.