Technical Specifications of Schneider Easy TeSys 65A 240V AC 3P Contactor LC1E65U5:

SpecValue
Product Component TypeContactor
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
Power Dissipation Per Pole4.2 W AC-36.4 W AC-1
Tightening TorqueControl circuit: 1.2 N.mPower circuit: 5 N.m

Schneider Easy TeSys 65A 240V AC 3P Contactor LC1E65U5 Technical Specifications:

SpecificationValue
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current65 A (at <55 °C) at <= 440 V AC AC-3 for power circuit80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage240 V AC 50 Hz
Motor power kW18.5 kW at 220...230 V AC 50/60 Hz (AC-3)30 kW at 380...400 V AC 50/60 Hz (AC-3)37 kW at 415 V AC 50/60 Hz (AC-3)37 kW at 440 V AC 50/60 Hz (AC-3)37 kW at 500 V AC 50/60 Hz (AC-3)37 kW at 660...690 V AC 50/60 Hz (AC-3)
Pole contact composition3 NO
[Ith] conventional free air thermal current80 A (at 55 °C)
Irms rated making capacity650 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity520 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current520 A 40 °C - 10 s for power circuit260 A 40 °C - 60 s for power circuit110 A 40 °C - 600 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1125 A gG at <= 690 V coordination type 1 for power circuit
Power dissipation per pole4.2 W AC-36.4 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50 Hz0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA160 VA 50 Hz cos phi 0.75 (at 20 °C)140 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA15 VA 50 Hz cos phi 0.3 (at 20 °C)13 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation6…10 W for control circuit
Operating time20...26 ms on closing8...12 ms on opening
Maximum operating rate1200 cyc/h 60 °C
Connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.mPower circuit: 5 N.m
Auxiliary contact composition1 NO + 1 NC
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Mounting supportPlateDIN rail
IP degree of protectionIP2X conforming to IEC 60529
Height127 mm
Width75 mm
Depth114 mm
Net weight0.98 kg
IndMALL Automation Dealing offers Schneider Easy TeSys 65A 240V AC 3P Contactor LC1E65U5 at unbeatable prices. The Main Technical Parameters of LC1E65U5 are Easy TeSys Control Range of products and the Contactor Product or component type 3P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 65 A (at <55 °C) at <= 440 V AC AC-3 for power circuit80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit. It operates at a control circuit voltage of 240 V AC 50 Hz, with 3 NO poles. The conventional free air thermal current is rated at 80 A (at 55 °C), and power dissipation per pole is 4.2 W AC-36.4 W AC-1. The rated insulation voltage is 690 V conforming to IEC 60947-4-1, and the impulse withstand voltage is 6 kV coil not connected to the power circuit conforming to IEC 60947. Take the First Step with a Quote for your requirement of Schneider Easy TeSys 65A 240V AC 3P Contactor. Choose us for unparalleled pricing and support over other Dealers & Distributors.