Technical Specifications of Schneider Easy TeSys Contactor 60A 220V AC 4P LC1E80004B7IN:
Spec | Value |
---|---|
Product Component Type | Contactor |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
Power Dissipation Per Pole | 5.1 W AC-39.7 W AC-1 |
Tightening Torque | Control circuit: 1.2 N.mPower circuit: 12 N.m |
Schneider Easy TeSys Contactor 60A 220V AC 4P LC1E80004B7IN Technical Specifications:
Specification | Value |
---|---|
Range | Easy TeSys |
Range of product | Easy TeSys Control |
Product or component type | Contactor |
Poles description | 4P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current | 110 A (at <40 °C) at <= 415 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 24 V AC 50/60 Hz |
Pole contact composition | 4 NO |
[Ith] conventional free air thermal current | 110 A (at 40 °C) for power circuit |
Irms rated making capacity | 800 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 640 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 640 A 40 °C - 10 s for power circuit320 A 40 °C - 60 s for power circuit135 A 40 °C - 600 s for power circuit |
Associated fuse rating | 160 A gG at <= 690 V coordination type 1 for power circuit conforming to IEC 60947-5-1 |
Power dissipation per pole | 5.1 W AC-39.7 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
Control circuit type | AC at 50/60 Hz |
Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50/60 Hz0.3...0.6 Uc (-5…55 °C):drop-out 50/60 Hz |
Inrush power in VA | 200 VA 50 Hz cos phi 0.75 (at 20 °C)220 VA 60 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 22 VA 60 Hz cos phi 0.3 (at 20 °C)20 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 6…10 W for control circuit |
Operating time | 20...35 ms on closing6...30 ms on opening |
Maximum operating rate | 1200 cyc/h 60 °C |
Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 4…50 mm² - cable stiffness: solid without cable end |
Tightening torque | Control circuit: 1.2 N.mPower circuit: 12 N.m |
Mounting support | DIN railPlate |
IP degree of protection | IP2X conforming to IEC 60529 |
Height | 127 mm |
Width | 95 mm |
Depth | 120 mm |
Net weight | 1.6 kg |
Obtain a Quote for Schneider Easy TeSys Contactor 60A 220V AC 4P LC1E80004B7IN at economical prices. Specifications Overview for LC1E80004B7IN reveals Easy TeSys Control Range of products and the Contactor Product or component type 4P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 110 A (at <40 °C) at <= 415 V AC AC-1 for power circuit. It operates at a control circuit voltage of 24 V AC 50/60 Hz, with 4 NO poles. Take the First Step with a Quote for your requirement of Schneider Easy TeSys Contactor 60A 220V AC 4P. Our commitment to better pricing and exceptional support sets us apart from other Competitors.