LC1G185LSEA: Schneider TeSys Giga High Power Contactor
Technical Specifications of Schneider TeSys Giga High Power Contactor LC1G185LSEA:
Spec | Value |
---|---|
Power Dissipation Per Pole | 20 W AC-1 - Ith 305 A6 W AC-3 - Ith 185 A |
Range of Product | TeSys Giga |
Pole Contact Composition | 3 NO |
Connection Terminals | Power circuit: bar 2 - busbar cross section: 25 x 6 mmPower circuit: lugs-ring terminals 1 185 mm²Power circuit: bolted connectionControl circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5…1.0 mm² with cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end |
Schneider TeSys Giga High Power Contactor LC1G185LSEA Technical Specifications:
Specification | Value |
---|---|
Device short name | LC1G |
Power dissipation per pole | 20 W AC-1 - Ith 305 A6 W AC-3 - Ith 185 A |
Ambient air temperature for operation | -25…60 °C |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz<= 460 V DC |
Range of product | TeSys Giga |
Rated breaking capacity | 1610 A at 440 V |
Auxiliary contact composition | 1 NO + 1 NC |
Maximum operating rate | 600 cyc/h AC-3600 cyc/h AC-3e300 cyc/h AC-1150 cyc/h AC-4 |
Width | 108 mm |
Poles description | 3P |
Utilisation category | AC-1AC-3AC-3eAC-4AC-5aAC-5bAC-6aAC-6bAC-8bAC-8aDC-1DC-3DC-5 |
Colour | Dark grey |
Control circuit voltage limits | Operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C)Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C) |
Motor power hp | 50 hp at 200/208 V 60 Hz60 hp at 230/240 V 60 Hz125 hp at 460/480 V 60 Hz150 hp at 575/600 V 60 Hz |
Height | 255 mm |
Mechanical durability | 8 Mcycles |
[Ie] rated operational current | 305 A (at <40 °C) at <= 1000 V AC-1185 A (at <60 °C) at <= 440 V AC-3 |
Operating time | 40...70 ms closing15...50 ms opening |
Pole contact composition | 3 NO |
Ambient air temperature for storage | -60…80 °C |
Product or component type | Contactor |
[Uc] control circuit voltage | 200...500 V AC 50/60 Hz200...500 V DC |
Tightening torque | 18 N.m |
Depth | 193 mm |
Associated fuse rating | 200 A aM at <= 440 V for motor160 A aM at <= 690 V for motor315 A gG at <= 690 V |
[Icw] rated short-time withstand current | 1.5 kA - 10 s0.92 kA - 30 s0.74 kA - 1 min0.5 kA - 3 min0.4 kA - 10 min |
Motor power kW | 55 kW at 230 V AC 50/60 Hz (AC-3e)90 kW at 400 V AC 50/60 Hz (AC-3e)90 kW at 415 V AC 50/60 Hz (AC-3e)110 kW at 440 V AC 50/60 Hz (AC-3e)110 kW at 500 V AC 50/60 Hz (AC-3e)110 kW at 690 V AC 50/60 Hz (AC-3e)75 kW at 1000 V AC 50/60 Hz (AC-3e)55 kW at 230 V AC 50/60 Hz (AC-3)90 kW at 400 V AC 50/60 Hz (AC-3)90 kW at 415 V AC 50/60 Hz (AC-3)110 kW at 440 V AC 50/60 Hz (AC-3)110 kW at 500 V AC 50/60 Hz (AC-3)110 kW at 690 V AC 50/60 Hz (AC-3)75 kW at 1000 V AC 50/60 Hz (AC-3)55 kW at 230 V AC 50/60 Hz (AC-4)90 kW at 400 V AC 50/60 Hz (AC-4)90 kW at 415 V AC 50/60 Hz (AC-4)100 kW at 440 V AC 50/60 Hz (AC-4)110 kW at 500 V AC 50/60 Hz (AC-4)110 kW at 690 V AC 50/60 Hz (AC-4)75 kW at 1000 V AC 50/60 Hz (AC-4) |
Net weight | 4.1 kg |
IP degree of protection | IP2X front face with shrouds conforming to IEC 60529IP2X front face with shrouds conforming to VDE 0106 |
hold-in power consumption in W (DC) | 8.0 W |
Range | TeSys |
Connections - terminals | Power circuit: bar 2 - busbar cross section: 25 x 6 mmPower circuit: lugs-ring terminals 1 185 mm²Power circuit: bolted connectionControl circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5…1.0 mm² with cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end |
[Uimp] rated impulse withstand voltage | 8 kV |
Mounting support | Plate |
Connection pitch | 35 mm |
[Ui] rated insulation voltage | 1000 V |
Ask for the Pricing of Schneider TeSys Giga High Power Contactor LC1G185LSEA at unbeatable prices. Detailed Specifications of LC1G185LSEA features device short name LC1G, designed for efficient power management in industrial applications. The sensor has a power dissipation per pole of 20 W AC-1 - Ith 305 A6 W AC-3 - Ith 185 A, ensuring energy-efficient operation. It operates within a broad ambient temperature range of -25…60 °C, making it suitable for various environmental conditions. The rated operational voltage [Ue] is up to <= 1000 V AC 50/60 Hz<= 460 V DC, providing robust power handling. Its rated breaking capacity reaches 1610 A at 440 V, ensuring reliable performance during switching. The auxiliary contact composition includes 1 NO + 1 NC, enhancing flexibility in control applications. With the mechanical durability of 8 Mcycles, the sensor guarantees long-lasting reliability. Operating times include a closing time of 40...70 ms closing15...50 ms opening quick and responsive operation. Now's the Time to Secure a Quote for your requirement of Schneider TeSys Giga High Power Contactor. We're committed to offering more favorable pricing and more responsive support than other Traders.