LC1G265LSEA: Schneider Advanced Contactor 200-500V Coil
Technical Specifications of Schneider Advanced Contactor 200-500V Coil LC1G265LSEA:
Spec | Value |
---|---|
Power Dissipation Per Pole | 20 W AC-1 - Ith 385 A11 W AC-3 - Ith 265 A |
Range of Product | TeSys Giga |
Pole Contact Composition | 3 NO |
Connection Terminals | Power circuit: bar 2 - busbar cross section: 32 x 10 mmPower circuit: lugs-ring terminals 1 185 mm²Power circuit: bolted connectionControl circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5…1.0 mm² with cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end |
Schneider Advanced Contactor 200-500V Coil LC1G265LSEA Technical Specifications:
Specification | Value |
---|---|
Device short name | LC1G |
Power dissipation per pole | 20 W AC-1 - Ith 385 A11 W AC-3 - Ith 265 A |
Ambient air temperature for operation | -25…60 °C |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz<= 460 V DC |
Range of product | TeSys Giga |
Rated breaking capacity | 2380 A at 440 V |
Auxiliary contact composition | 1 NO + 1 NC |
Maximum operating rate | 600 cyc/h AC-3600 cyc/h AC-3e300 cyc/h AC-1150 cyc/h AC-4 |
Width | 140 mm |
Poles description | 3P |
Utilisation category | AC-1AC-3AC-3eAC-4AC-5aAC-5bAC-6aAC-6bAC-8bAC-8aDC-1DC-3DC-5 |
Colour | Dark grey |
Control circuit voltage limits | Operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C)Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C) |
Motor power hp | 75 hp at 200/208 V 60 Hz100 hp at 230/240 V 60 Hz200 hp at 460/480 V 60 Hz200 hp at 575/600 V 60 Hz |
Height | 290 mm |
Mechanical durability | 8 Mcycles |
[Ie] rated operational current | 385 A (at <40 °C) at <= 1000 V AC-1265 A (at <60 °C) at <= 440 V AC-3 |
Operating time | 40...70 ms closing15...50 ms opening |
Pole contact composition | 3 NO |
Ambient air temperature for storage | -60…80 °C |
Product or component type | Contactor |
[Uc] control circuit voltage | 200...500 V AC 50/60 Hz200...500 V DC |
Tightening torque | 35 N.m |
Depth | 226 mm |
Associated fuse rating | 315 A aM at <= 440 V for motor250 A aM at <= 690 V for motor400 A gG at <= 690 V |
[Icw] rated short-time withstand current | 2.2 kA - 10 s1.23 kA - 30 s0.95 kA - 1 min0.62 kA - 3 min0.48 kA - 10 min |
Motor power kW | 75 kW at 230 V AC 50/60 Hz (AC-3e)132 kW at 400 V AC 50/60 Hz (AC-3e)132 kW at 415 V AC 50/60 Hz (AC-3e)160 kW at 440 V AC 50/60 Hz (AC-3e)160 kW at 500 V AC 50/60 Hz (AC-3e)200 kW at 690 V AC 50/60 Hz (AC-3e)160 kW at 1000 V AC 50/60 Hz (AC-3e)75 kW at 230 V AC 50/60 Hz (AC-3)132 kW at 400 V AC 50/60 Hz (AC-3)132 kW at 415 V AC 50/60 Hz (AC-3)160 kW at 440 V AC 50/60 Hz (AC-3)160 kW at 500 V AC 50/60 Hz (AC-3)200 kW at 690 V AC 50/60 Hz (AC-3)160 kW at 1000 V AC 50/60 Hz (AC-3)75 kW at 230 V AC 50/60 Hz (AC-4)132 kW at 400 V AC 50/60 Hz (AC-4)132 kW at 415 V AC 50/60 Hz (AC-4)150 kW at 440 V AC 50/60 Hz (AC-4)160 kW at 500 V AC 50/60 Hz (AC-4)160 kW at 690 V AC 50/60 Hz (AC-4)160 kW at 1000 V AC 50/60 Hz (AC-4) |
Net weight | 8.2 kg |
IP degree of protection | IP2X front face with shrouds conforming to IEC 60529IP2X front face with shrouds conforming to VDE 0106 |
hold-in power consumption in W (DC) | 9.0 W |
Range | TeSys |
Connections - terminals | Power circuit: bar 2 - busbar cross section: 32 x 10 mmPower circuit: lugs-ring terminals 1 185 mm²Power circuit: bolted connectionControl circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5…1.0 mm² with cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end |
[Uimp] rated impulse withstand voltage | 8 kV |
Mounting support | Plate |
Connection pitch | 45 mm |
[Ui] rated insulation voltage | 1000 V |
Mail Us for your needs in Schneider Advanced Contactor 200-500V Coil LC1G265LSEA with budget-friendly prices. The Main Technical Parameters of LC1G265LSEA include device short name LC1G, designed for efficient power management in industrial applications. The sensor has a power dissipation per pole of 20 W AC-1 - Ith 385 A11 W AC-3 - Ith 265 A, ensuring energy-efficient operation. It operates within a broad ambient temperature range of -25…60 °C, making it suitable for various environmental conditions. The rated operational voltage [Ue] is up to <= 1000 V AC 50/60 Hz<= 460 V DC, providing robust power handling. Its rated breaking capacity reaches 2380 A at 440 V, ensuring reliable performance during switching. The auxiliary contact composition includes 1 NO + 1 NC, enhancing flexibility in control applications. With the mechanical durability of 8 Mcycles, the sensor guarantees long-lasting reliability. Operating times include a closing time of 40...70 ms closing15...50 ms opening quick and responsive operation. Customize Your Experience with a Quote for your requirement of Schneider Advanced Contactor 200-500V Coil. Experience the difference with our competitive pricing and superior support over other Suppliers.