Technical Specifications of Schneider 20 A 4 NO TeSys K Contactor LC1K09004B7:

SpecValue
[Uc] control circuit voltage24 V AC 50/60 Hz
Auxiliary Contact Composition-
Mounting SupportPlateRail
Inrush power in W-

Schneider 20 A 4 NO TeSys K Contactor LC1K09004B7 Technical Specifications:

SpecificationValue
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solidScrew clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable endScrew clamp terminals 2 cable(s) 1.5…4 mm²solidScrew clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
[Uc] control circuit voltage24 V AC 50/60 Hz
Minimum switching voltage-
contactor applicationResistive load
Width45 mm
Control circuit typeAC at 50/60 Hz
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Depth57 mm
[Ie] rated operational current20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit16 A (at <70 °C) at 690 V AC AC-1 for power circuit
Auxiliary contacts type-
poles description4P
Auxiliary contact composition-
IP degree of protectionIP2X conforming to VDE 0106
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V conforming to CSA C22.2 No 14
Operating altitude2000 m without derating
Ambient air temperature for operation-
Power pole contact composition4 NO
Hold-in power consumption in W-
Ambient air temperature for storage-50…80 °C
Utilisation categoryAC-1
Insulation resistance-
Heat dissipation1.3 W
Hold-in power consumption in VA4.5 VA (at 20 °C)
Net weight0.18 kg
Minimum switching current-
Mounting supportPlateRail
Operating time10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closing
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
Product or component typeContactor
Tightening torque0.8…1.3 N.m - on screw clamp terminals Philips No 20.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
Maximum operating rate3600 cyc/h
RangeTeSys
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz
Height58 mm
Motor power kW-
Inrush power in W-
[Uimp] rated impulse withstand voltage8 kV
Electrical durability0.16 Mcycles 20 A AC-1 at Ue <= 690 V
Device short nameLC1K
Please speak to our Technical Engineer for Schneider 20 A 4 NO TeSys K Contactor LC1K09004B7 at attractive prices. Technical Specs Summary of LC1K09004B7 includes control circuit voltage [Uc] operates at 24 V AC 50/60 Hz, with a minimum switching voltage of -, ensuring responsive operation. It is suitable for both motor Resistive load applications. The control circuit type is AC at 50/60 Hz, and the auxiliary contacts are - configuration, providing reliable switching. The sensor features a 4P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. The utilization categories include AC-1, making it suitable for a wide range of applications. Product or component type Contactor. Match Your Needs with a Quote for your requirement of Schneider 20 A 4 NO TeSys K Contactor. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.