LC1K090085E7: Schneider Industrial 20A 4P Contactor
Technical Specifications of Schneider Industrial 20A 4P Contactor LC1K090085E7:
Spec | Value |
---|---|
[Uc] control circuit voltage | 48 V AC 50/60 Hz |
Auxiliary Contact Composition | - |
Mounting Support | Printed circuit boards |
Inrush power in W | - |
Schneider Industrial 20A 4P Contactor LC1K090085E7 Technical Specifications:
Specification | Value |
---|---|
Connections - terminals | Solder pins (external diameter: 0.035 mm) |
[Uc] control circuit voltage | 48 V AC 50/60 Hz |
Minimum switching voltage | - |
contactor application | Resistive load |
Width | 45 mm |
Control circuit type | AC at 50/60 Hz |
Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Depth | 57 mm |
[Ie] rated operational current | 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
Auxiliary contacts type | - |
poles description | 4P |
Auxiliary contact composition | - |
IP degree of protection | IP2X conforming to VDE 0106 |
[Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V conforming to CSA C22.2 No 14 |
Operating altitude | 2000 m without derating |
Ambient air temperature for operation | - |
Power pole contact composition | 2 NO + 2 NC |
Hold-in power consumption in W | - |
Ambient air temperature for storage | -50…80 °C |
Utilisation category | AC-1 |
Insulation resistance | - |
Heat dissipation | 1.3 W |
Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
Net weight | 0.18 kg |
Minimum switching current | - |
Mounting support | Printed circuit boards |
Operating time | 10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closing15...25 ms coil de-energisation and NC closing5...15 ms coil energisation and NC opening |
Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
Product or component type | Contactor |
Tightening torque | - |
Maximum operating rate | 3600 cyc/h |
Range | TeSys |
[Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz |
Height | 58 mm |
Motor power kW | - |
Inrush power in W | - |
[Uimp] rated impulse withstand voltage | 8 kV |
Electrical durability | 0.16 Mcycles 20 A AC-1 at Ue <= 690 V |
Device short name | LC1K |
Mail Us for your needs in Schneider Industrial 20A 4P Contactor LC1K090085E7 with budget-friendly prices. The Main Technical Parameters of LC1K090085E7 include control circuit voltage [Uc] operates at 48 V AC 50/60 Hz, with a minimum switching voltage of -, ensuring responsive operation. It is suitable for both motor Resistive load applications. The control circuit type is AC at 50/60 Hz, and the auxiliary contacts are - configuration, providing reliable switching. The sensor features a 4P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. The utilization categories include AC-1, making it suitable for a wide range of applications. Product or component type Contactor. Customize Your Experience with a Quote for your requirement of Schneider Industrial 20A 4P Contactor. Experience the difference with our competitive pricing and superior support over other Suppliers.