LC1K0901Q7 | Schneider 9A TeSys K Contactor 400VAC Coil
+91 79955 44066 sales@indmall.in

LC1K0901Q7: Schneider 9A TeSys K Contactor 400VAC Coil

Technical Specifications of Schneider 9A TeSys K Contactor 400VAC Coil LC1K0901Q7:

SpecValue
Power pole contact composition3 NO
Control Circuit TypeAC 50/60 Hz
Inrush power in W-
Connection Terminalsscrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end

Schneider 9A TeSys K Contactor 400VAC Coil LC1K0901Q7 Technical Specifications:

SpecificationValue
RangeTeSys
Product or Component TypeContactor
Device short name-
Contactor applicationMotor controlResistive load
Utilisation categoryAC-3AC-3eAC-1AC-4
Poles description3P
Power pole contact composition3 NO
[Ue] rated operational voltagePower circuit <= 690 V AC <= 400 HzSignalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Control circuit type [Uc]AC 50/60 Hz
Control circuit voltage380...400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 140 °F (60 °C)) for power circuit10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 122 °F (50 °C) - 1 s for power circuit85 A 122 °F (50 °C) - 5 s for power circuit80 A 122 °F (50 °C) - 10 s for power circuit60 A 122 °F (50 °C) - 30 s for power circuit45 A 122 °F (50 °C) - 1 min for power circuit40 A 122 °F (50 °C) - 3 min for power circuit20 A 122 °F (50 °C) - >= 15 min for power circuit80 A - 1 s for signalling circuit90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage-
Inrush power in W-
Hold-in power consumption in W-
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at <122 °F (50 °C))Drop-out: >= 0.20 Uc (at <122 °F (50 °C))
Connections - terminalsscrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Maximum operating rate3600 cyc/h
Mounting Support-
Operating time10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closing
Height2.3 in (58 mm)
Width1.8 in (45 mm)
Depth2.2 in (57 mm)
Net Weight-
IP degree of protection-
Ambient air temperature for operation-
Ambient Air Temperature for Storage-
Operating altitude6561.68 ft (2000 m) without derating
Get A Quote for Schneider 9A TeSys K Contactor 400VAC Coil LC1K0901Q7 at the best price. Here are the brief Technical Specifications of LC1K0901Q7 are Contactor Product or Component Type 3 NO power pole contact composition. This contactor operates with a rated operational voltage of up to Power circuit <= 690 V AC <= 400 HzSignalling circuit <= 690 V AC <= 400 Hz, ensuring flexibility in various industrial applications. The control circuit operates on a AC 50/60 Hz with a control voltage of 380...400 V AC 50/60 Hz, providing reliable control functionality. It has a rated impulse withstand voltage of 8 kV, conforming to industry standards for electrical safety. The compact design includes a height of 2.3 in (58 mm), a width of 1.8 in (45 mm), and a depth of 2.2 in (57 mm). It's Time to get a Quote for your requirement of Schneider 9A TeSys K Contactor 400VAC Coil. We guarantee unmatched pricing and unparalleled support compared to other Distributors.