LP1K09004BD: Schneider 20A 4P TeSys K Contactor
Technical Specifications of Schneider 20A 4P TeSys K Contactor LP1K09004BD:
Spec | Value |
---|---|
[Uc] control circuit voltage | 24 V DC |
Auxiliary Contact Composition | - |
Mounting Support | RailPlate |
Inrush power in W | 3 W (at 20 °C) |
Schneider 20A 4P TeSys K Contactor LP1K09004BD Technical Specifications:
Specification | Value |
---|---|
Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solidScrew clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable endScrew clamp terminals 2 cable(s) 1.5…4 mm²solidScrew clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end |
[Uc] control circuit voltage | 24 V DC |
Minimum switching voltage | - |
contactor application | Resistive load |
Width | 45 mm |
Control circuit type | DC standard |
Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Depth | 57 mm |
[Ie] rated operational current | 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
Auxiliary contacts type | - |
poles description | 4P |
Auxiliary contact composition | - |
IP degree of protection | IP2X |
[Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V conforming to CSA C22.2 No 14 |
Operating altitude | 2000 m without derating |
Ambient air temperature for operation | -25…50 °C |
Power pole contact composition | 4 NO |
Hold-in power consumption in W | 3 W at 20 °C |
Ambient air temperature for storage | -50…80 °C |
Utilisation category | AC-1 |
Insulation resistance | - |
Heat dissipation | 1.3 W |
Hold-in power consumption in VA | - |
Net weight | 0.225 kg |
Minimum switching current | - |
Mounting support | RailPlate |
Operating time | 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening |
Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
Product or component type | Contactor |
Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 20.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
Maximum operating rate | 3600 cyc/h |
Range | TeSys |
[Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz |
Height | 58 mm |
Motor power kW | 4 kW at 690 V AC 50/60 Hz AC-4 |
Inrush power in W | 3 W (at 20 °C) |
[Uimp] rated impulse withstand voltage | 8 kV |
Electrical durability | 0.16 Mcycles 20 A AC-1 at Ue <= 690 V |
Device short name | LP1K |
Please speak to our Technical Engineer for Schneider 20A 4P TeSys K Contactor LP1K09004BD at attractive prices. Technical Specs Summary of LP1K09004BD includes control circuit voltage [Uc] operates at 24 V DC, with a minimum switching voltage of -, ensuring responsive operation. It is suitable for both motor Resistive load applications. The control circuit type is DC standard, and the auxiliary contacts are - configuration, providing reliable switching. The sensor features a 4P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. The utilization categories include AC-1, making it suitable for a wide range of applications. Product or component type Contactor. Match Your Needs with a Quote for your requirement of Schneider 20A 4P TeSys K Contactor. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.