LP1K09004JD: Schneider 4P TeSys K Contactor 12VDC Coil
Technical Specifications of Schneider 4P TeSys K Contactor 12VDC Coil LP1K09004JD:
Spec | Value |
---|---|
Power pole contact composition | 4 NO |
Control Circuit Type | DC standard |
Inrush power in W | 3 W 68 °F (20 °C)) |
Connection Terminals | screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable endPower circuit screw clamp terminals 2 0.002 in² (1.5 mm²)flexible with cable end |
Schneider 4P TeSys K Contactor 12VDC Coil LP1K09004JD Technical Specifications:
Specification | Value |
---|---|
Range | TeSys |
Product or Component Type | Contactor |
Device short name | LP1K |
Contactor application | Resistive load |
Utilisation category | AC-1 |
Poles description | 4P |
Power pole contact composition | 4 NO |
[Ue] rated operational voltage | Power circuit <= 690 V AC <= 400 HzSignalling circuit <= 690 V AC <= 400 Hz |
[Ie] rated operational current | 20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit |
Control circuit type [Uc] | DC standard |
Control circuit voltage | 12 V DC |
[Uimp] rated impulse withstand voltage | 8 kV |
Overvoltage category | III |
[Ith] conventional free air thermal current | 20 A (at 140 °F (60 °C)) for power circuit10 A (at 122 °F (50 °C)) for signalling circuit |
Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947 |
Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
[Icw] rated short-time withstand current | 90 A 122 °F (50 °C) - 1 s for power circuit85 A 122 °F (50 °C) - 5 s for power circuit80 A 122 °F (50 °C) - 10 s for power circuit60 A 122 °F (50 °C) - 30 s for power circuit45 A 122 °F (50 °C) - 1 min for power circuit40 A 122 °F (50 °C) - 3 min for power circuit20 A 122 °F (50 °C) - >= 15 min for power circuit |
Associated fuse rating | 25 A gG at <= 440 V for power circuit25 A aM for power circuit |
Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
[Ui] rated insulation voltage | Power circuit 600 V UL 508Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSA C22.2 No 14 |
Inrush power in W | 3 W 68 °F (20 °C)) |
Hold-in power consumption in W | 3 W 68 °F (20 °C) |
Heat dissipation | 1.3 W |
Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <122 °F (50 °C))Drop-out: >= 0.10 Uc (at <122 °F (50 °C)) |
Connections - terminals | screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable endPower circuit screw clamp terminals 2 0.002 in² (1.5 mm²)flexible with cable end |
Maximum operating rate | 3600 cyc/h |
Mounting Support | PlateRail |
Operating time | 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening |
Height | 2.3 in (58 mm) |
Width | 1.8 in (45 mm) |
Depth | 2.2 in (57 mm) |
Net Weight | 0.496 lb(US) (0.225 kg) |
IP degree of protection | IP2X |
Ambient air temperature for operation | -13…122 °F (-25…50 °C) |
Ambient Air Temperature for Storage | -58…176 °F (-50…80 °C) |
Operating altitude | 6561.68 ft (2000 m) without derating |
Get A Quote for Schneider 4P TeSys K Contactor 12VDC Coil LP1K09004JD at the best price. Here are the brief Technical Specifications of LP1K09004JD are Contactor Product or Component Type 4 NO power pole contact composition. This contactor operates with a rated operational voltage of up to Power circuit <= 690 V AC <= 400 HzSignalling circuit <= 690 V AC <= 400 Hz, ensuring flexibility in various industrial applications. The control circuit operates on a DC standard with a control voltage of 12 V DC, providing reliable control functionality. It has a rated impulse withstand voltage of 8 kV, conforming to industry standards for electrical safety. The compact design includes a height of 2.3 in (58 mm), a width of 1.8 in (45 mm), and a depth of 2.2 in (57 mm). It's Time to get a Quote for your requirement of Schneider 4P TeSys K Contactor 12VDC Coil. We guarantee unmatched pricing and unparalleled support compared to other Distributors.