LP4K0601BW3: Schneider Contactor With 6A Capacity
Technical Specifications of Schneider Contactor With 6A Capacity LP4K0601BW3:
Spec | Value |
---|---|
[Uc] control circuit voltage | 24 V DC |
Auxiliary Contact Composition | 1 NC |
Mounting Support | PlateRail |
Inrush power in W | 1.8 W (at 20 °C) |
Schneider Contactor With 6A Capacity LP4K0601BW3 Technical Specifications:
Specification | Value |
---|---|
Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solidScrew clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable endScrew clamp terminals 2 cable(s) 1.5…4 mm²solidScrew clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end |
[Uc] control circuit voltage | 24 V DC |
Minimum switching voltage | 17 V for signalling circuit |
contactor application | Motor control |
Width | 45 mm |
Control circuit type | DC wide range |
Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Depth | 57 mm |
[Ie] rated operational current | 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
Auxiliary contacts type | type instantaneous 1 NC |
poles description | 3P |
Auxiliary contact composition | 1 NC |
IP degree of protection | IP2X |
[Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
Operating altitude | 2000 m without derating |
Ambient air temperature for operation | -25…50 °C |
Power pole contact composition | 3 NO |
Hold-in power consumption in W | 1.8 W at 20 °C |
Ambient air temperature for storage | -50…80 °C |
Utilisation category | AC-3AC-3eAC-4 |
Insulation resistance | > 10 MOhm for signalling circuit |
Heat dissipation | 1.8 W |
Hold-in power consumption in VA | - |
Net weight | 0.235 kg |
Minimum switching current | 5 mA for signalling circuit |
Mounting support | PlateRail |
Operating time | 10...20 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing |
Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
Product or component type | Contactor |
Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 20.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
Maximum operating rate | 3600 cyc/h |
Range | TeSys |
[Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz |
Height | 58 mm |
Motor power kW | 1.5 kW at 220...230 V AC 50/60 Hz AC-32.2 kW at 380...415 V AC 50/60 Hz AC-33 kW at 440/690 V AC 50/60 Hz AC-31.5 kW at 220...230 V AC 50/60 Hz AC-3e2.2 kW at 380...415 V AC 50/60 Hz AC-3e3 kW at 440/690 V AC 50/60 Hz AC-3e1.5 kW at 220...230 V AC 50/60 Hz AC-42.2 kW at 380...415 V AC 50/60 Hz AC-43 kW at 440/690 V AC 50/60 Hz AC-4 |
Inrush power in W | 1.8 W (at 20 °C) |
[Uimp] rated impulse withstand voltage | 8 kV |
Electrical durability | 1.3 Mcycles 6 A AC-3 at Ue <= 440 V1.3 Mcycles 6 A AC-3e at Ue <= 440 V0.05 Mcycles 36 A AC-4 at Ue <= 440 V |
Device short name | LP4K |
Ask for the Pricing of Schneider Contactor With 6A Capacity LP4K0601BW3 at unbeatable prices. Detailed Specifications of LP4K0601BW3 features control circuit voltage [Uc] operates at 24 V DC, with a minimum switching voltage of 17 V for signalling circuit, ensuring responsive operation. It is suitable for both motor Motor control applications. The control circuit type is DC wide range, and the auxiliary contacts are type instantaneous 1 NC configuration, providing reliable switching. The sensor features a 3P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.8 W, it is energy efficient. The utilization categories include AC-3AC-3eAC-4, making it suitable for a wide range of applications. Product or component type Contactor. Now's the Time to Secure a Quote for your requirement of Schneider Contactor With 6A Capacity. We're committed to offering more favorable pricing and more responsive support than other Traders.