TM200C40R | Schneider M200 40 IO Relay Controller | IndMALL
+91 79955 44066 sales@indmall.in

TM200C40R: Schneider M200 40 IO Relay Controller

Technical Specifications of Schneider M200 40 IO Relay Controller TM200C40R:

SpecValue
Sensor Power Supply24 V DC at 300 mA supplied by the controller
Power consumption in VA59…69 VA at 100...240 V AC (with max I/O)
Discrete Input Voltage24 V
Discrete Output TypeRelay normally open

Schneider M200 40 IO Relay Controller TM200C40R Technical Specifications:

SpecificationValue
Protection type-
Sensor power supply24 V DC at 300 mA supplied by the controller
Discrete input current7 mA for input
Ambient air temperature for operation0…55 °C (horizontal installation)
Power consumption in VA59…69 VA at 100...240 V AC (with max I/O)
Power consumption in W-
Depth70 mm
Output frequency-
[Us] rated supply voltage100...240 V AC
Discrete output number16 relay
Maximum voltage drop-
Transmission rate1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS4851.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS23212 Mbit/s for USB
Maximum cable distance between devicesUnshielded cable: <50 m for inputShielded cable: <10 m for fast inputShielded cable: <10 m for high speed inputUnshielded cable: <150 m for output
Communication port protocolUSB port: USB - SoMachine-NetworkNon isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Width175 mm
Output voltage limits30 V DC250 V AC
Net weight0.504 kg
Memory capacity512 byte internal flash for backup of programs
Supply voltage limits85…264 V
Discrete output current2 A
Discrete output logic-
Electrical durability100000 cycles AC-12, 240 V, 480 VA, resistive100000 cycles DC-12, 24 V, 48 W, resistive
Discrete input voltage24 V
Maximum number of I/O expansion module4 with 128 discrete output(s) for transistor output4 with 80 discrete output(s) for relay output
Maximum current per output common4 A at COM 24 A at COM 04 A at COM 14 A at COM 3
Inrush current50 A
Discrete output typeRelay normally open
Network frequency50/60 Hz
Discrete input numberI2...I5: 4 fast inputI0, I1, I6, I7: 4 high speed inputI8...I23: 16 regular input
Ambient air temperature for storage-25…70 °C
Electrical connectionMini B USB 2.0 connectorfor a programming terminal removable screw terminal blockfor inputs removable screw terminal blockfor outputs removable screw terminal block, 4 terminal(s) for connecting the serial link1 removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply
Call us for Schneider M200 40 IO Relay Controller TM200C40R at the best rates. Technical Attributes of TM200C40R are discrete input current of 7 mA for input and supports ambient air temperatures from 0…55 °C (horizontal installation), ensuring reliable performance in various environments. It runs on a rated supply voltage [Us] of 100...240 V AC, providing flexibility in power input. The sensor features 16 relay outputs, each with a discrete input voltage of 24 V. It handles a maximum current of 4 A at COM 24 A at COM 04 A at COM 14 A at COM 3, making it suitable for demanding tasks. With an inrush current of 50 A, the sensor delivers fast and effective power handling. The discrete output type is Relay normally open, ensuring safe and efficient switching. Unlock Exclusive Pricing with a Quote for your requirement of Schneider M200 40 IO Relay Controller. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.