TM221CE16U: Schneider M221 16 IO NPN Transistor Controller
Technical specifications of Schneider M221 16 IO NPN Transistor Controller TM221CE16U y1gl*62915c9:
Spec | Value |
---|---|
[Us] rated supply voltage | 24 V DC |
IP degree of protection | IP20 with protective cover in place |
Supply voltage limits | 20.4…28.8 V |
Ambient air temperature for operation | -10…55 °C (horizontal installation)-10…35 °C (vertical installation) |
Protection type | Without protection |
Schneider M221 16 IO NPN Transistor Controller TM221CE16U Technical Specifications:
Specification | Value |
---|---|
Electromagnetic emission | Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011 |
Resistance to electrostatic discharge | 8 kV in air conforming to IEC 61000-4-24 kV on contact conforming to IEC 61000-4-2 |
Ambient air temperature for storage | -25…70 °C |
Power supply output current | 0.325 A 5 V for expansion bus0.15 A 24 V for expansion bus |
Discrete output voltage | 24 V DC |
Discrete input voltage | 24 V DC |
IP degree of protection | IP20 with protective cover in place |
[Us] rated supply voltage | 24 V DC |
Standards | IEC 61131-2UL 508CAN/CSA C22.2 No. 213IACS E10ANSI/ISA 12-12-01 |
Response time | 35 µs turn-off, I2...I5 terminal(s) for input5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input35 µs turn-on, other terminals terminal(s) for input5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input100 µs turn-off, other terminals terminal(s) for input5 µs turn-on, turn-off, Q0...Q1 terminal(s) for output50 µs turn-on, turn-off, Q2...Q3 terminal(s) for output300 µs turn-on, turn-off, other terminals terminal(s) for output |
Immunity to microbreaks | 10 ms |
Relative humidity | 10…95 %, without condensation (in operation)10…95 %, without condensation (in storage) |
Transmission rate | 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS4851.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232480 Mbit/s for USB |
Maximum power consumption in W | 11 W at 24 V (with max number of I/O expansion module)4.6 W at 24 V (without I/O expansion module) |
Ambient air temperature for operation | -10…55 °C (horizontal installation)-10…35 °C (vertical installation) |
Discrete input current | 7 mA for discrete input5 mA for fast input |
Supply voltage limits | 20.4…28.8 V |
Maximum voltage drop | <1 V |
Surge withstand | 2 kV power lines (AC) common mode conforming to IEC 61000-4-52 kV relay output common mode conforming to IEC 61000-4-51 kV I/O common mode conforming to IEC 61000-4-51 kV shielded cable common mode conforming to IEC 61000-4-50.5 kV power lines (DC) differential mode conforming to IEC 61000-4-51 kV power lines (AC) differential mode conforming to IEC 61000-4-51 kV relay output differential mode conforming to IEC 61000-4-50.5 kV power lines (DC) common mode conforming to IEC 61000-4-5 |
Discrete output current | 0.5 A |
Port Ethernet | 10BASE-T/100BASE-TX 1 port with 100 m copper cable |
Vibration resistance | 3.5 mm at 5…8.4 Hz on symmetrical rail3.5 mm at 5…8.4 Hz on panel mounting1 gn at 8.4…150 Hz on symmetrical rail1 gn at 8.4…150 Hz on panel mounting |
Communication port protocol | USB port: USB - SoMachine-NetworkNon isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-NetworkEthernet |
Shock resistance | 147 m/s² for 11 ms |
Protection type | Without protection |
Mail Us for your needs in Schneider M221 16 IO NPN Transistor Controller TM221CE16U with budget-friendly prices. The Main Technical Parameters of TM221CE16U include ambient air storage temperatures ranging from -25…70 °C, ensuring durability under various conditions. It features 4 fast input (HSC mode) at 100 kHz 32 bits resolution, ideal for precise operations. The package width is 80.0 cm, and it supports a discrete output voltage of 24 V DC, with Transistor-type outputs. The discrete input voltage type is DC, and the sensor comes equipped with 7 transistor 2 fast output outputs for enhanced performance. The discrete input current is 7 mA for discrete input5 mA for fast input inputs. With a compact depth of 70 mm, this sensor integrates seamlessly into industrial setups, supporting a total of 16 discrete I/O points. It is designed to operate at altitudes up to 0...2000 m, making it suitable for a wide range of applications. Customize Your Experience with a Quote for your requirement of Schneider M221 16 IO NPN Transistor Controller. Experience the difference with our competitive pricing and superior support over other Suppliers.