Sick Flush and Non-flush Sensor CM12-08EBP-KW1, 6051029 Technical Specifications:
Specification
Value
Housing
Cylindrical thread design
Thread size
M12 x 1
Diameter
Ø 12 mm
Sensing range Sn
0.5 mm ... 8 mm 1), 0.5 mm ... 4 mm 2)
Safe sensing range Sa
5.76 mm
Installation type
Non-flush / flush
Switching frequency
15 Hz
Connection type
2m Cable
Switching output
PNP / NPN
Output function
Programmable
Output characteristic
Wire configurable 4)
Electrical wiring
DC 4-wire
Adjustment
Single teach-in button (Sensitivity)
Cable (Sensitivity)
Enclosure rating
IP68 (According to EN 60529) 6)
Items supplied
Mounting nut, PA12 plastic (2x)
Reach Us by Email for Sick Flush and Non-flush Sensor CM12-08EBP-KW1 part no: 6051029 at Discounted Rates. Key Technical Features of CM12-08EBP-KW1, 6051029 are Cylindrical thread design housing, M12 x 1 thread size, Ø 12 mm diameter, 0.5 mm ... 8 mm 1), 0.5 mm ... 4 mm 2) sensing range, Non-flush / flush Installation, 15 Hz frequency, 2m Cable, PNP / NPN, DC 4-wire, Programmable output. Navigate Your Needs with a Quote for your requirement of Sick Flush and Non-flush Sensor. Our pricing and support are unrivaled, especially when compared to other Competitors.