LMS4111R-13000: 1091423 - Sick Visible Red Light LiDAR Sensor
Technical Specifications of Sick Visible Red Light LiDAR Sensor LMS4111R-13000 1091423:
Spec | Value |
---|---|
Light Source | Visible red light (660 nm) |
Connection Type | 1 x M12, 5-pin plug (Power + I/O + Sync), 1 x M12, 8-pin female connector (Ethernet), 1 x M12, 5-pin female connector (Encoder + I/O) |
Dimensions (L x W x H) | 192 mm x 130 mm x 107 mm |
Digital outputs | 3 |
Sick Visible Red Light LiDAR Sensor LMS4111R-13000, 1091423 Technical Specifications:
Specification | Value |
---|---|
Application | Indoor |
Light source | Visible red light (660 nm) |
Laser class | 2 (IEC 60825-1:2014, EN 60825-1:2014) |
Aperture angle | Horizontal, 70° |
Scanning frequency | 600 Hz |
Angular resolution | 0.0833° |
Heating | - |
Working range | 0.7 m ... 3 m |
Scanning range | At 2% remission, 2.3 m. At 3,5% remission, 3 m. At 10% remission factor, 3 m. |
Connection type | 1 x M12, 5-pin plug (Power + I/O + Sync), 1 x M12, 8-pin female connector (Ethernet), 1 x M12, 5-pin female connector (Encoder + I/O) |
Supply voltage | 24 V DC, ± 25 % |
Power consumption | ≤ 16 W, start-up phase max. 29 W |
Housing | Aluminum die cast |
Housing color | Light blue (RAL 5012) |
Enclosure rating | IP65 |
Protection class | III |
Weight | 2.4 kg |
Dimensions (L x W x H) | 192 mm x 130 mm x 107 mm |
MTBF | 80 years |
MTTFD | > 100 years |
Detectable object shape | Almost any |
Systematic error | ± 1.5 mm |
Statistical error | 2.5 mm |
Ethernet | ✔ , TCP/IP, UDP/IP. Function, Measurement data output (distance, RSSI, angle). Data transmission rate, 100 Mbit/s ... 1,000 Mbit/s, half/full-duplex. |
Serial | - |
Digital outputs | 3 |
Optical indicators | 4 LEDs |
Ambient operating temperature | –10 °C ... +50 °C |
Storage temperature | –20 °C ... +70 °C |
Reach Us by Email for Sick Visible Red Light LiDAR Sensor LMS4111R-13000 part no: 1091423 at Discounted Rates. Key Technical Features of LMS4111R-13000, 1091423 are Indoor applications, using an Visible red light (660 nm) light source and classified as Laser Class 2 (IEC 60825-1:2014, EN 60825-1:2014). It offers a Horizontal, 70° aperture angle with a scanning frequency of 600 Hz and operates within a working range of 0.7 m ... 3 m, with a scanning range At 2% remission, 2.3 m. At 3,5% remission, 3 m. At 10% remission factor, 3 m.. It connects 1 x M12, 5-pin plug (Power + I/O + Sync), 1 x M12, 8-pin female connector (Ethernet), 1 x M12, 5-pin female connector (Encoder + I/O) and requires a 24 V DC, ± 25 % supply voltage, consuming ≤ 16 W, start-up phase max. 29 W for heating. colored Light blue (RAL 5012), with an IP65 enclosure rating and protection class III. The dimensions of 192 mm x 130 mm x 107 mm. The MTBF is 80 years, and MTTFD is > 100 years. The sensor has a systematic error of ± 1.5 mm and a statistical error of 2.5 mm, 3 output. It operates between –10 °C ... +50 °C and can be stored between –20 °C ... +70 °C. Navigate Your Needs with a Quote for your requirement of Sick Visible Red Light LiDAR Sensor. Our pricing and support are unrivaled, especially when compared to other Competitors.