Technical Specifications of Sick Flexi Loop Safety Relay RLY3-LOOP100 1100696:
Spec | Value |
---|---|
Safety Integrity Level | SIL 3 (IEC 61508) |
Connection Types | Front connector with spring terminals |
Outputs | 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) |
Configuration Method | Hard wired, DIP switch |
Sick Flexi Loop Safety Relay RLY3-LOOP100, 1100696 Technical Specifications:
Specification | Value |
---|---|
Compatible sensor types | Flexi Loop safe series connection |
Safety integrity level | SIL 3 (IEC 61508) |
Category | Category 4 (ISO 13849-1) |
Performance level | PL e (ISO 13849-1) |
TM (mission time) | 20 years (ISO 13849-1) |
Sensor monitoring | ✔ |
Restart interlock | ✔ |
Reset | Automatic, Manual |
External device monitoring (EDM) | ✔ |
Connection type | Front connector with spring terminals |
Inputs | 2 safety inputs, 1 input for reset pushbutton or external device monitoring (EDM) |
Outputs | 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) |
Display elements | LEDs |
Configuration method | Hard wired, DIP switch |
Supply voltage VS | 24 V DC (16.8 V ... 30 V) |
Residual ripple | ≤ 2.4 V |
Power consumption | ≤ 2.5 W (DC) |
Input voltage HIGH | 24 V DC (11 V ... 30 V) |
Input voltage LOW | 0 V DC (–3 V ... 5 V) |
Input current | 4 mA ... 6 mA |
Test pulse width | - |
Test pulse rate | - |
Response time | 79 ms |
Type of output | N/O contacts, positively guided |
Contact material | Silver alloy, gold flashed |
Switching voltage | 10 V AC ... 230 V AC, 10 V DC ... 230 V DC |
Switching current | 10 mA ... 6 A |
Total current | 12 A |
Overvoltage category | III (EN 60664-1) |
Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |
Output voltage HIGH | ≥ Vs – 3 V |
Output voltage LOW | ≤ 3 V |
Input current (NPN) | ≤ 15 mA |
Output current (PNP) | ≤ 120 mA |
Output voltage | ≥ Vs – 3 V |
Test pulse interval | 40 ms |
Dimensions (W x H x D) | 18 mm x 124.6 mm x 85.5 mm |
Enclosure rating | IP20 (IEC 60529) |
Ambient operating temperature | –25 °C ... +55 °C |
Storage temperature | –25 °C ... +70 °C |
Air humidity | ≤ 95 %, Non-condensing |
Interference emission | According to IEC 61000-6-4 |
Interference resistance | According to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1 |
Weight | 160 g |
Please speak to our Technical Engineer for Sick Flexi Loop Safety Relay RLY3-LOOP100 part no: 1100696 at attractive prices. Technical Specs Summary of RLY3-LOOP100, 1100696 features Flexi Loop safe series connection and meets SIL 3 (IEC 61508), Category 4 (ISO 13849-1) and PL e (ISO 13849-1) standards with a 20 years (ISO 13849-1) mission time. It features ✔, Automatic, Manual reset. The relay has a Front connector with spring terminals, 2 safety inputs, 1 input for reset pushbutton or external device monitoring (EDM). Outputs include 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) and LEDs for display elements and is configured through a Hard wired, DIP switch method. It supports 24 V DC (16.8 V ... 30 V) supply voltage, ≤ 2.4 V residual ripple, and ≤ 2.5 W (DC) power consumption. The relay operates with input voltage high at 24 V DC (11 V ... 30 V) and low at 0 V DC (–3 V ... 5 V), with an input current of 4 mA ... 6 mA . with a response time of 79 ms.
The relay has N/O contacts, positively guided, Silver alloy, gold flashed supporting 10 V AC ... 230 V AC, 10 V DC ... 230 V DC switching voltage, and 10 mA ... 6 A switching current and a total current of 12 A. Output voltage HIGH is ≥ Vs – 3 V, and output voltage LOW is ≤ 3 V. The input current (NPN) is ≤ 15 mA, and the output current (PNP) is ≤ 120 mA, with an output voltage of ≥ Vs – 3 V and a test pulse interval of 40 ms. The dimensions of 18 mm x 124.6 mm x 85.5 mm and an IP20 (IEC 60529) enclosure rating. It operates in ambient temperatures of –25 °C ... +55 °C and storage temperatures of –25 °C ... +70 °C, with air humidity of ≤ 95 %, Non-condensing. Match Your Needs with a Quote for your requirement of Sick Flexi Loop Safety Relay. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.