RLY3-OSSD100 | 1085343 - Sick OSSD Safety Relay | IndMALL
+91 79955 44066 sales@indmall.in

RLY3-OSSD100: 1085343 - Sick OSSD Safety Relay

Technical Specifications of Sick OSSD Safety Relay RLY3-OSSD100 1085343:

SpecValue
Safety Integrity LevelSIL 3 (IEC 61508)
Connection TypesFront connector with spring terminals
Outputs2 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe)
Configuration Method-

Sick OSSD Safety Relay RLY3-OSSD100, 1085343 Technical Specifications:

SpecificationValue
Compatible sensor typesSafety sensors with OSSDs
Safety integrity levelSIL 3 (IEC 61508)
CategoryCategory 4 (ISO 13849-1)
Performance levelPL e (ISO 13849-1)
TM (mission time)20 years (ISO 13849-1)
Sensor monitoring-
Restart interlock-
Reset-
External device monitoring (EDM)
Connection typeFront connector with spring terminals
Inputs2 safety inputs
Outputs2 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe)
Display elementsLEDs
Configuration method-
Supply voltage VS-
Residual ripple-
Power consumption≤ 1.5 W (DC)
Input voltage HIGH24 V DC (11 V ... 30 V)
Input voltage LOW0 V DC (–3 V ... 5 V)
Input current≤ 50 mA
Test pulse width≤ 1 ms
Test pulse rate≤ 10 Hz
Response time12 ms
Type of outputN/O contacts, positively guided
Contact materialSilver alloy, gold flashed
Switching voltage10 V AC ... 230 V AC, 10 V DC ... 230 V DC
Switching current10 mA ... 6 A
Total current12 A
Overvoltage categoryIII (EN 60664-1)
Rated impulse withstand voltage Uimp6 kV (EN 60664-1)
Output voltage HIGH-
Output voltage LOW-
Input current (NPN)-
Output current (PNP)-
Output voltage-
Test pulse interval-
Dimensions (W x H x D)18 mm x 124.6 mm x 85.5 mm
Enclosure ratingIP20 (IEC 60529)
Ambient operating temperature–25 °C ... +55 °C
Storage temperature–25 °C ... +70 °C
Air humidity≤ 95 %, Non-condensing
Interference emissionAccording to IEC 61000-6-4
Interference resistanceAccording to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1
Weight130 g
Obtain a Quote for Sick OSSD Safety Relay RLY3-OSSD100 part no: 1085343 at economical prices. Specifications Overview for RLY3-OSSD100, 1085343 features Safety sensors with OSSDs and meets SIL 3 (IEC 61508), Category 4 (ISO 13849-1) and PL e (ISO 13849-1) standards with a 20 years (ISO 13849-1) mission time. It features -, - reset. The relay has a Front connector with spring terminals, 2 safety inputs. Outputs include 2 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe) and ≤ 1.5 W (DC) power consumption. The relay operates with input voltage high at 24 V DC (11 V ... 30 V) and low at 0 V DC (–3 V ... 5 V), with an input current of ≤ 50 mA . The test pulse width is ≤ 1 ms, and the test pulse rate is ≤ 10 Hz, with a response time of 12 ms. The relay has N/O contacts, positively guided, Silver alloy, gold flashed supporting 10 V AC ... 230 V AC, 10 V DC ... 230 V DC switching voltage, and 10 mA ... 6 A switching current and a total current of 12 A. The dimensions of 18 mm x 124.6 mm x 85.5 mm and an IP20 (IEC 60529) enclosure rating. It operates in ambient temperatures of –25 °C ... +55 °C and storage temperatures of –25 °C ... +70 °C, with air humidity of ≤ 95 %, Non-condensing. Take the First Step with a Quote for your requirement of Sick OSSD Safety Relay. Our commitment to better pricing and exceptional support sets us apart from other Competitors.