RLY3-TIME100 | 1100688 - Sick Safety Control Relay | IndMALL
+91 79955 44066 sales@indmall.in

RLY3-TIME100: 1100688 - Sick Safety Control Relay

Technical Specifications of Sick Safety Control Relay RLY3-TIME100 1100688:

SpecValue
Safety Integrity LevelSIL 3 (IEC 61508)
Connection TypesFront connector with spring terminals
Outputs2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
Configuration MethodHard wired, DIP switch

Sick Safety Control Relay RLY3-TIME100, 1100688 Technical Specifications:

SpecificationValue
Compatible sensor typesSafety sensors with OSSDs, Safety sensors with potential-free outputs
Safety integrity levelSIL 3 (IEC 61508)
CategoryCategory 4 (ISO 13849-1)
Performance levelPL e (ISO 13849-1)
TM (mission time)20 years (ISO 13849-1)
Sensor monitoringDiscrepancy monitoring, Sequence monitoring, Cross-circuit detection
Restart interlock
ResetAutomatic, Manual
External device monitoring (EDM)
Connection typeFront connector with spring terminals
Inputs2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM)
Outputs2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
Display elementsLEDs
Configuration methodHard wired, DIP switch
Supply voltage VS24 V DC (16.8 V ... 30 V)
Residual ripple≤ 2.4 V
Power consumption≤ 2.5 W (DC)
Input voltage HIGH24 V DC (11 V ... 30 V)
Input voltage LOW0 V DC (–3 V ... 5 V)
Input current4 mA ... 6 mA
Test pulse width≤ 1 ms
Test pulse rate≤ 10 Hz
Response time12 ms
Type of outputN/O contacts, positively guided
Contact materialSilver alloy, gold flashed
Switching voltage10 V AC ... 230 V AC, 10 V DC ... 230 V DC
Switching current10 mA ... 6 A
Total current12 A
Overvoltage categoryIII (EN 60664-1)
Rated impulse withstand voltage Uimp6 kV (EN 60664-1)
Output voltage HIGH≥ Vs – 3 V
Output voltage LOW≤ 3 V
Input current (NPN)≤ 15 mA
Output current (PNP)≤ 120 mA
Output voltage≥ Vs – 3 V
Test pulse interval40 ms
Dimensions (W x H x D)18 mm x 124.6 mm x 85.5 mm
Enclosure ratingIP20 (IEC 60529)
Ambient operating temperature–25 °C ... +55 °C
Storage temperature–25 °C ... +70 °C
Air humidity≤ 95 %, Non-condensing
Interference emissionAccording to IEC 61000-6-4
Interference resistanceAccording to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1
Weight160 g
SIL 3 (IEC 61508)