Technical Specifications of Sick Area Scanner S30A-7011BA:
Spec | Value |
---|---|
Protective field range | 7 m |
Dimensions (W x H x D) | 155 mm x 185 mm x 160 mm |
Supply voltage Vs | 24 V DC (16.8 V DC ... 28.8 V DC) |
Connection type | - |
Sick Area Scanner S30A-7011BA, 1023890 Technical Specifications:
Specification | Value |
---|---|
Sub product family | - |
Application | Indoor |
Protective field range | 7 m |
Warning field range | 49 m (20 m at 20 % reflectivity) |
Number of simultaneously monitored fields | ≤ 4 |
Number of fields | 4 |
Number of monitoring cases | 1 |
Scanning angle | 190° |
Angular resolution | 0.5°, 0.25°, depending on range and resolution |
Resolution (can be configured) | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm |
Response time | 60 ms |
Protective field supplement | 100 mm |
Type | Type 3 (IEC 61496) |
Safety integrity level | SIL 2 (IEC 61508) |
Category | Category 3 (EN ISO 13849) |
Performance level | PL d (EN ISO 13849) |
TM (mission time) | 20 years (EN ISO 13849) |
Safe state in the event of a fault | At least one OSSD is in the OFF state. |
Connection type | - |
Universal I/Os | - |
Outputs/OSSD pairs | - |
Configuration method | - |
Configuration and diagnostics interface | - |
Display elements | - |
Protection class | II (EN 50178) |
Supply voltage Vs | 24 V DC (16.8 V DC ... 28.8 V DC) |
Power consumption typical | ≤ 0.8 A , ≤ 2.3 A |
Dimensions (W x H x D) | 155 mm x 185 mm x 160 mm |
Weight | 3.3 kg |
Housing material | Aluminum die cast |
Housing color | RAL 1021 (yellow) |
Optics cover material | Polycarbonate |
Optics cover surface finish | Outside with scratch-resistant coating |
Enclosure rating | IP65 (EN 60529) |
Ambient operating temperature | –10 °C ... +50 °C |
Type of light | Pulsed laser diode |
Wave length | 905 nm |
Give Us a Call for Sick Area Scanner S30A-7011BA part no: 1023890 at the lowest pricing. In-depth Technical Analysis of S30A-7011BA, 1023890 features Laser Safety Scanner is designed for Indoor applications, offering a protective field range of 7 m and a warning field range of 49 m (20 m at 20 % reflectivity). It can monitor ≤ 4 fields simultaneously, with 4 configurable fields and 1 monitoring cases. The scanner features a 190° scanning angle and an angular resolution of 0.5°, 0.25°, depending on range and resolution. It supports configurable resolutions of 30 mm, 40 mm, 50 mm, 70 mm, 150 mm and a response time of 60 ms. Classified as Type 3 (IEC 61496) with SIL 2 (IEC 61508) and Category 3 (EN ISO 13849), achieving a PL d (EN ISO 13849) performance level and a mission time of 20 years (EN ISO 13849) operates at 24 V DC (16.8 V DC ... 28.8 V DC), and consumes ≤ 0.8 A , ≤ 2.3 A. Dimensions are 155 mm x 185 mm x 160 mm, and the housing is Aluminum die cast with RAL 1021 (yellow) colors, with a Polycarbonate optics cover having a Outside with scratch-resistant coating. It is rated IP65 (EN 60529) and operates in temperatures from –10 °C ... +50 °C, type of light is a Pulsed laser diode at 905 nm wave length. Elevate Your Project with a Quote for your requirement of Sick Area Scanner. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.